Study on the Bond Strength of Steel-Concrete Composite Rectangular Fluted Sections
نویسندگان
چکیده
منابع مشابه
Effect of the Concrete Strength on the Concrete-Steel Bond in Concrete Filled Steel Tubes
In this study, the concrete-steel bond strength of concrete filled cylindrical steel tubes has been experimentally investigated. 22 short, high strength and normal concrete filled circular steel tubes were tested. Push-out test was carried out as the common method to evaluate the bond carrying capacity. Four different concrete mixes were used in preparing the specimens. The steel tubes were w...
متن کاملthe effect of taftan pozzolan on the compressive strength of concrete in the environmental conditions of oman sea (chabahar port)
cement is an essential ingredient in the concrete buildings. for production of cement considerable amount of fossil fuel and electrical energy is consumed. on the other hand for generating one tone of portland cement, nearly one ton of carbon dioxide is released. it shows that 7 percent of the total released carbon dioxide in the world relates to the cement industry. considering ecological issu...
Bond of High Strength Concrete with High Strength Reinforcing Steel
This paper presents a study about the bond of high strength concrete with high strength steel. Fourteen pull out tests were carried out to determine the bond. The concrete strength was about 70 MPa and the steel was a 500 MPa grade. Bar diameters used were 12, 16, 20, 25, 28, 32 and 36 mm. In order to investigate the effect of cover, each test was done twice, once in a 240 mm diameter concrete ...
متن کاملFlexural Performance of High-strength Prestressed Concrete-encased Concrete-filled Steel Tube Sections
The sections composed of concrete and steel, which include concrete-encased concrete-filled tubes, generally have defects due to the low tensile strength of concrete. Therefore, an appropriate method was used for the combination of concrete-filled tubes (CFT) and prestressing strands which is encased in concrete. The conventional design guidelines are commonly developed for materials with norma...
متن کاملEffect of Impressed Current on Bond Strength Between Steel Rebar and Concrete
The deterioration of bond strength between reinforcing steel and concrete as a result of impressed cathodic current with respect to the exposure time was investigated. A current in the magnitude of 3ma/ft2 (based on reinforcing rebar area) was used for a period of five years. Chemical analyses for sodium (Na+), potassium (K+) and chloride (Cl-) ions in concrete cylinders were performed as a fun...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Advances in Civil Engineering
سال: 2020