Suction Socket of the Artificial Limb

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pseudo-Kaposi's sarcoma because of suction-socket lower limb prosthesis.

Pseudo-Kaposi sarcoma is a benign reactive vascular proliferation mainly involving the lower legs, which can be related to acquired chronic venous insufficiency or congenital arteriovenous malformations. In its most common presentation, acroangiodermatitis is seen in patients with chronic venous insufficiency of the lower limbs as an exaggeration of the stasis dermatitis. However, rare reports ...

متن کامل

The Evolution of Upper Limb Prosthetic Socket Design

Well thought out socket designs and careful consideration of residual limb presentation set the stage for patient success—maximizing range of motion, providing stability throughout daily activities, and comfortably distributing the forces exerted on the residual limb during movement and suspension. In contrast, poor socket design will often drive people to abandon the prosthesis because many pa...

متن کامل

Status of the above-knee suction socket in the United States.

1 HE above-knee suction socket constitutes a means of attaching an artificial leg to the stump of an amputee without necessity for the conventional pelvic band, a metal hip joint, or other types of suspension harness (Fig. 1). The leg is held on by the slight vacuum created in the socket each time the leg is lifted from the ground, the pressure usually being controlled by a valve installed in t...

متن کامل

3-D Turbulence Numerical Simulation for the Flow Field of Suction Cylinder-Seeder with Socket-Slots

The flow field has significantly impact on seeding performance in the suction seeding device. A three-dimensional, incompressible, viscous, RNG turbulence model and the SIMPLE method were used by computational fluid dynamics(CFD), and the flow fields of suction cylinder-seeder with different socket’s radiuses were simulated by Fluent. When vacuum is 4kPa and productivity is 350 trays/h, the sim...

متن کامل

A comparison of trans-tibial amputee suction and vacuum socket conditions.

Daily volume loss of the stump leads to a poor fit of the prosthetic socket. A method of preventing this volume loss and maintaining a good fit was developed. A vacuum (-78 kPa) was drawn on the expulsion port of a total surface-bearing suction socket to hold the liner tightly against the socket. Stump volume of 10 trans-tibial amputees was measured prior to and immediately after a 30 minute wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Orthopedics & Traumatology

سال: 1953

ISSN: 1349-4333,0037-1033

DOI: 10.5035/nishiseisai.2.93