Surface Damage Is Not Reduced With Highly Crosslinked Polyethylene Tibial Inserts at Short-term

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wear of highly crosslinked polyethylene acetabular components

BACKGROUND AND PURPOSE Wear rates of highly crosslinked polyethylene (XLPE) acetabular components have varied considerably between different published studies. This variation is in part due to the different techniques used to measure wear and to the errors inherent in measuring the relatively low amounts of wear in XLPE bearings. We undertook a scoping review of studies that have examined the i...

متن کامل

Vivacit-E® Vitamin E Highly Crosslinked Polyethylene Long-term Performance For High Demand Patients

Total joint replacement is being performed on younger patients who expect to remain active throughout their lifetime, and as such this demographic shift has created a need for long-term implant bearing performance. First introduced in the 1990s, highly crosslinked polyethylene (HXPE) has demonstrated promising wear properties through the first decade of in vivo use. Recent studies, however, hav...

متن کامل

An experimental approach to determining fatigue crack size in polyethylene tibial inserts.

A major limiting factor to the longevity of prosthetic knee joints is fatigue crack damage of the polyethylene tibial insert. Existing methods to quantify fatigue crack damage have several shortcomings, including limited resolution, destructive testing approach, and high cost. We propose an alternative fatigue crack damage visualization and measurement method that addresses the shortcomings of ...

متن کامل

Fracture of Two Moderately Cross-Linked Polyethylene Tibial Inserts in a TKR Patient

Highly cross-linked polyethylene has become the gold standard in total hip replacement for its wear resistance. Moderately crosslinked polyethylene is now available for total knee replacement (TKR), although concerns about reduced mechanical strength have prevented widespread adoption. The purpose of this report is to describe an unusual case where a patient underwent cruciate retaining TKR usi...

متن کامل

Dielectric Study at Microwave Frequencies of Water-treed Crosslinked Polyethylene

The dielectric properties of water-treed crosslinked polyethylene (XLPE) were studied by using a hollow microwave waveguide system between 135 MHz and 13.6 GH5. The dielectric loss of water-treed XLPE is proportional to water content. Water-treed XLPE has a low relaxation frequency which is probably due to bound water. The binding of water in trees was confirmed by the lower apparent water diff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Clinical Orthopaedics & Related Research

سال: 2016

ISSN: 0009-921X

DOI: 10.1007/s11999-015-4344-4