The Infusion Rate Select Mode of a Disposable Continuous Infusion Pump Induce a Large Variation in the Infusion Rate.
نویسندگان
چکیده
منابع مشابه
Disposable infusion pumps.
PURPOSE The properties, performance, and applications of nonelectric disposable infusion pumps are reviewed. SUMMARY All nonelectric disposable infusion pumps exploit the same physical principle: mechanical restriction within the flow path determines the speed of pressurized fluid. The pressure generated by disposable pumps on fluid is 250-600 mm Hg, compared with 5-1200 mm Hg of pressure for...
متن کاملAccurate continuous drug delivery at low infusion rate with a novel microvolumetric infusion pump (MVIP): pump design, evaluation and comparison to the current standard.
Infusion devices for continuous and precise drug administration are indispensable tools in anaesthesia and critical care medicine. Problems such as start-up delays, non-continuous flow and susceptibility to hydrostatic pressure changes at low infusion rates resulting in accidental bolus release or prolonged flow interruption are inherent to current infusion technology. In order to improve preci...
متن کاملInterscalene brachial plexus block with a continuous catheter insertion system and a disposable infusion pump.
Continuous interscalene brachial plexus blockade traditionally requires a hospital stay for local anesthetic infusion, and achieving consistent catheter insertion may be difficult. Incorporating long-acting pain relief from a continuous peripheral nerve block, with a reliable method of catheter insertion, and a self-contained infusion system would be a valuable asset for short-stay care. We com...
متن کاملContinuous bilateral posterior lumbar plexus block with a disposable infusion pump: case report.
BACKGROUND AND OBJECTIVES The number of bilateral total hip arthroplasties (THA) has been increasing every year. Postoperative analgesia by continuous perineural infusion of local anesthetic has been shown favorable results when compared to systemic analgesia. The use of elastomeric pumps has increased patient satisfaction when compared to electronic models. The objective of this report was to ...
متن کاملThe Variable Rate Intravenous Insulin Infusion Protocol
Insulin use among inpatients is high and associated with severe and regular medication errors. An initial baseline audit showed a wide variation in the prescription of intravenous insulin within the trust. These included variation in the choice of fluid prescribed, electrolyte levels not consistently checked, handwritten illegible prescriptions, and varying parameters set for adjustment of the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: THE JOURNAL OF JAPAN SOCIETY FOR CLINICAL ANESTHESIA
سال: 2000
ISSN: 0285-4945,1349-9149
DOI: 10.2199/jjsca.20.123