The ion sensitive field effect transistor (ISFET) pH electrode: a new sensor for long term ambulatory pH monitoring.

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The ion sensitive field effect transistor (ISFET) pH electrode: a new sensor for long term ambulatory pH monitoring.

Intraluminal pH monitoring in man should be performed with disposable multichannel assemblies that allow recordings at multiple sites and prevent transmission of infection. Currently available glass electrodes are unsuitable for this purpose because of their size and price. We have thus constructed and tested a small, combined ion sensitive field effect transistor (ISFET) pH electrode incorpora...

متن کامل

Ion-sensitive field effect transistor as a pH sensor.

In this work, both the static and dynamic behaviors as well as the signal read-out circuits of ISFETs were studied. The standard NMOS structure in conjunction with the insulator-electrolyte capacitor was used to model the ISFET under study. The site-binding theory was incorporated to describe the chemistry occurring at the insulator/electrolyte interface. The mechanism of the threshold voltage ...

متن کامل

fabrication of new ion sensitive field effect transistors (isfet) based on modification of junction-fet for analysis of hydronium, potassium and hydrazinium ions

a novel and ultra low cost isfet electrode and measurement system was designed for isfet application and detection of hydronium, hydrazinium and potassium ions. also, a measuring setup containing appropriate circuits, suitable analyzer (advantech board), de noise reduction elements, cooling system and pc was used for controlling the isfet electrode and various characteristic measurements. the t...

Field effect transistor with integrated microfluidic channel as pH sensor

This paper presents an original design of chemical sensors with an integrated microfluidic channel. Targeted applications are pH-meters devices. The integration of the microfluidic channel allows decreasing the volume required for each measurement. The sensing part of the device consists of a field effect transistor with a suspended gate directly performed above the fluidic channel. Chemicals u...

متن کامل

Ambulatory esophageal pH monitoring: new directions.

pH testing remains a commonly used evaluative tool in clinical practice. However, the original tool that included a nasally placed pH catheter was plagued with a variety of shortcomings, primarily the effect of the procedure on patients' lifestyle and thus on reflux-provoking activities. The miniaturization of evaluative techniques in gastroenterology was the impetus for the development of the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Gut

سال: 1991

ISSN: 0017-5749

DOI: 10.1136/gut.32.3.240