The MINOS light-injection calibration system
نویسندگان
چکیده
منابع مشابه
The MINOS Light Injection Calibration System
A description is given of the light-injection calibration system that has been developed for the MINOS long-baseline neutrino oscillation experiment. The system is based upon pulsed blue LEDs monitored by PIN photodiodes. It is designed to measure non-linearities in the PMT gain curves, as well as monitoring any drifts in PMT gain, at the 1% level.
متن کامل0 v 1 2 6 O ct 1 99 8 Ultra Bright LED Light Injection Calibration System for MINOS
We describe here a proposal for a light injection calibration system for the MINOS detectors based on ultra bright blue LEDs as the light source. We have shown that these LEDs are bright enough to span over two orders of magnitude in light intensity, commensurate with that expected in a single scintillator strip in the MINOS neutrino detectors.
متن کاملContinuous System Calibration Using Non-visible Light
With the growing adoption of automatic systems for aligning the geometry of large multi-projector displays in venues such as flight or ship bridge simulators, it has become possible for even the most complicated visual systems to be realigned regularly to maintain seamless geometric alignment. Despite this ability, for the most part, these alignment systems still require that the system be take...
متن کاملNovel method for structured light system calibration
Peisen S. Huang, MEMBER SPIE State University of New York at Stony Brook Department of Mechanical Engineering Stony Brook, New York 11794 E-mail: [email protected] Abstract. System calibration, which usually involves complicated and time-consuming procedures, is crucial for any 3-D shape measurement system. In this work, a novel systematic method is proposed for accurate and quick cal...
متن کاملCalibration of a Structured Light System: A Projective Approach
We present in this paper a novel calibration method that uses cross ratio t o compute world points falling onto any given light stripe plane of a structured light system. We show that, by using 4 known non-coplanar sets of 3 collinear world points, the direct 4 x 3 imageto-world transformation matrix for each light stripe plane can also be recovered from plane-to-plane homography. Preliminary e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
سال: 2002
ISSN: 0168-9002
DOI: 10.1016/s0168-9002(02)01293-7