The new ALEPH Silicon Vertex Detector
نویسندگان
چکیده
منابع مشابه
SVX’, the new CDF silicon vertex detector
The Collider Detector at Fermilab (CDF) radiation hardened silicon vertex detector (SVX’) is described. The new detector has several improvements over its predecessor such as better signal to noise and higher efficiency. It is expected to have a radiation tolerance in excess of 1 Mrad. It has been taking data for several months and some preliminary results are shown.
متن کاملThe Belle Silicon Vertex Detector
The silicon vertex detector of the Belle experiment has been built to provide the vertex information of B meson decays at the KEKB accelerator. It consists of three cylindrical layers of double sided, double metal silicon sensors read out by VA1 chips. The analog signals are transmitted to a system of fast analog-to-digital converters and are reduced on a system based on Motorola Digital Signal...
متن کاملThe H1 silicon vertex detector
The design, construction and performance of the H1 silicon vertex detector is described. It consists of two cylindrical layers of double sided, double metal silicon sensors read out by a custom designed analog pipeline chip. The analog signals are transmitted by optical fibers to a custom designed ADC board and are reduced on PowerPC processors. Details of the design and construction are given ...
متن کاملProgress in the construction of the CDF silicon vertex detector
The mechanical design and construction progress of the CDF silicon vertex detector is described. Results on the location accuracy of the silicon strip detectors are presented and indicate an initial placement uncertainty of less than 10 Wm. The water and gas cooling system, which is constructed of low mass materials and is used to remove heat from the readout electronics, is briefly described ....
متن کاملLocal Alignment of the BABAR Silicon Vertex Tracking Detector
The BABAR Silicon Vertex Tracker (SVT) is a five-layer double-sided silicon detector designed to provide precise measurements of the position and direction of primary tracks, and to fully reconstruct low-momentum tracks produced in ee collisions at the PEP-II asymmetric collider at Stanford Linear Accelerator Center. This paper describes the design, implementation, performance, and validation o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
سال: 1998
ISSN: 0168-9002
DOI: 10.1016/s0168-9002(97)91255-9