Thermal Performance Assessment for an Active Latent Heat Storage Tank by Using Various Finned-Coil Heat Exchangers

نویسندگان

چکیده

Paraffin-based latent heat storage has a higher thermal capacity than sensible storage. Despite that, the actual implementation of paraffin as an active (ALHS) system is limited due to low charging and discharging rate with unequal temperature distribution impact mushy region formation. The present study evaluates finned-coil exchanger for ALHS tank overcome related problems. Three configurations are tested experimentally: straight-fin, branched-fin height-fin. evaluation uses arrangement assess each configuration's charging/discharging rate. branched fin provides equal distribution, promoting final 112.3°C. It also achieves highest power 250.5 Watts. height-fin minimizes effect void formation, which maintains sufficient transfer during discharging. However, average model relatively low. finding indicates that it essential provide adequate center part tank, including adding along coil turn better boosts rate, making system's response time desirable achieve effective operation.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thermal Performance of Borehole Heat Exchangers

An important issue in the design of systems using borehole heat exchangers is to find costeffective methods to construct the borehole heat exchanger so that heat can be injected or extracted from the ground without excessive temperature differences between the heat carrier fluid and the surrounding ground. This paper presents an overview of experiences and current activities in this field.

متن کامل

Full Analysis of Low Finned Tube Heat Exchangers

In this paper, first the governing parameters characterizing low-finned tubes are reviewed. Second, the more important of the available performance correlations are compared with the available experimental data. The most reliable one can be employed to develop a pressure drop relationship, which has already been used in an algorithm for exchanger sizing. Also a means for the identification of a...

متن کامل

Thermal performance of two heat exchangers for thermoelectric generators

The thermal performance of a heat exchanger is important for the potential application in an integrated solar cell/module and thermoelectric generator (TEG) system. Usually, the thermal performance of a heat exchanger for TEGs is analysed by using 1D heat conduction theory which ignores the detailed phenomena associated with thermo-hydraulics. In this paper, thermal and momentum transports in t...

متن کامل

Friction Loss and Heat Transfer Coefficient in Finned Tube Heat Exchangers for Reheating Massecuites

Equations developed for packed columns may be used to predict the overall heat transfer coefficient and friction loss in massecuite reheaters. The results seem to indicate that exchangers with the tubes staggered give higher heat transfer rates than those with the tubes in line.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Heat and Technology

سال: 2022

ISSN: ['0392-8764']

DOI: https://doi.org/10.18280/ijht.400615