Time to abandon nonionic contrast.

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time to abandon nonionic contrast.

E very year, over 1 0 million Intravascular contrast examinations are performed In the United States. A typical dose of 200 mL of high-osmolality Ionic radiographic contrast costs approximately $8 (e.g. , diatrizoate, iothalmate, and others). In comparIson , low-osmolality nonionic contrast costs up to $ 1 70 for equivalent volumes (e.g. , iopamldol. iohexol. and others). If nonlonic contrast w...

متن کامل

Expatriate failure: Time to abandon the concept?

In this article, we review the established understanding of the concept of expatriate failure, discuss its associated problems and present a more sophisticated and comprehensive understanding of the concept. We argue that it might well be time to abandon the concept of expatriate failure altogether and instead draw on the general HR literature to analyse problems related to turnover and perform...

متن کامل

An allergic reaction to intraarterial nonionic contrast material.

To the Editor: We report an incident of an allergic reaction to a small dose of intraarterial nonionic contrast material that was administered during cerebral angiography in a patient premedicated with steroids and antihistamines. A 23-year-old man with epilepsy was referred for cerebral angiography and Wada testing. These were performed for the purpose of language and memory testing before tem...

متن کامل

Bronchial vasodilatory response to ionic and nonionic contrast media.

It has recently been shown that bronchial arterial injection of conventional contrast medium causes a significant increase in bronchial blood flow (Qbr) and that this response is partially attenuated after infusion of N omega-nitro-L-arginine (L-NNA). However, the precise mechanism for this increase in Qbr is unknown. In this study we examined the effect of bronchial arterial injection of conve...

متن کامل

Pulmonary shunt fraction measurement compared to contrast echocardiography in hereditary haemorrhagic telangiectasia patients: time to abandon the 100% oxygen method?

BACKGROUND The presence of pulmonary right-to-left shunting (RLS) is associated with severe neurological complications from paradoxical embolisation in patients with hereditary haemorrhagic telangiectasia (HHT) and screening is warranted. Pulmonary shunt fraction measurement with the 100% oxygen method can be used for the detection and quantification of functional pulmonary RLS, although transt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the American Society of Nephrology

سال: 1994

ISSN: 1046-6673,1533-3450

DOI: 10.1681/asn.v52123