Tomographic image quality of rotating slat versus parallel hole-collimated SPECT

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tomographic image quality of rotating slat versus parallel hole-collimated SPECT.

Parallel and converging hole collimators are most frequently used in nuclear medicine. Less common is the use of rotating slat collimators for single photon emission computed tomography (SPECT). The higher photon collection efficiency, inherent to the geometry of rotating slat collimators, results in much lower noise in the data. However, plane integrals contain spatial information in only one ...

متن کامل

Fast 3D image reconstruction for rotating slat collimated gamma cameras

As an alternative to the use of traditional parallel hole collimators, SPECT imaging can be performed using rotating slat collimators. A gain in image quality could be expected from the higher photon collection efficiency, however, the plane integral data measured by this type of collimator require a reconstruction to invert the three-dimensional (3D) Radon transform. The use of iterative metho...

متن کامل

Graphics Hardware Accelerated Reconstruction of SPECT with a Slat Collimated Strip Detector

3D iterative reconstruction of Single Photon Emission Computed Tomography (SPECT) acquisitions is a widely used but computationaly intensive process. Reconstructing data from a rotating slat collimated system increases the computation time even further. Since the sensitivity profile of such a camera is not constant over the field of view, it is important to include a system model that is as acc...

متن کامل

Image quality of multisection CT of the brain: thickly collimated sequential scanning versus thinly collimated spiral scanning with image combining.

BACKGROUND AND PURPOSE Routine CT of the brain is traditionally performed with sequential CT. We assessed whether sequential CT can be replaced with thinly collimated multisection spiral CT without loss of image quality. MATERIALS AND METHODS An observer study was conducted using data from 23 patients who were scanned with both a sequential (collimation, 4 x 5 mm) and a spiral technique (coll...

متن کامل

Image reconstruction algorithm for a rotating slat collimator.

A slat collimator in single photon emission computed tomography consists of a set of parallel slats. As the collimator spins, the detector measures a one-dimensional projection data set. A complete data set can be obtained by rotating the detector/collimator assembly around the object (patient) while the collimator spins continuously. The measured projection data are assumed to be weighted plan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physics in Medicine and Biology

سال: 2011

ISSN: 0031-9155,1361-6560

DOI: 10.1088/0031-9155/56/22/013