In the TOMAS device, a triple Langmuir probe is used to measure electron temperature and density. The accuracy of this measurement depends on correct determination effective collecting area probe, which complex plasma transport processes. can be calibrated by cyclotron resonance heating experiments using cut-off density ordinary wave (O-wave). This threshold only frequency injected wave, occurrence phenomenon clearly visible in evolution. value consequently known at point calibrate measurements probe.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Double Langmuir probe measurement of plasma parameters in a dc glow discharge

In this paper, plasma main characteristics such as electron mean temperature, electron number density, and oscillation frequency have been measured experimentally using the double Langmuir probe diagnostic system. In our experiment, the plasma was generated by applying the low pressure dc glow discharge in several common gases. The experimental results indicated the highest plasma density and o...

متن کامل

Langmuir probe

Langmuir probes have been installed on satellites and sounding rockets to observe the general characteristics of thermal plasma in the ionosphere for more than five decades. Because of its simplicity and convenience, the Langmuir probe is one of the most frequently installed scientific instruments on spacecraft. While the algorithm to estimate the temperature and number density of thermal elect...

متن کامل

Langmuir probe measurements in an expanding magnetized plasma.

• A submitted manuscript is the author's version of the article upon submission and before peer-review. There can be important differences between the submitted version and the official published version of record. People interested in the research are advised to contact the author for the final version of the publication, or visit the DOI to the publisher's website. • The final author version ...

متن کامل

Influence of O2 and N2 Concentrations on the Characteristics of Plasma in DC Cylindrical Magnetron Discharge by Langmuir Probe

Using the Langmuir probe method, the reactive plasma parameters were studied in different ratios of oxygen and nitrogen concentrations in a DC cylindrical discharge device.The plasma parameters such as plasma potential, electron density and electron temperature wereextracted from the current-voltage characteristic’s curve of Langmuir probe to find the optimum conditions for deposit the oxy...

متن کامل

Calibration of Langmuir probes against microwaves and plasma oscillation probes

The use of Langmuir probes for measuring plasma density is subject to uncertainty because the theories commonly used to interpret the data give widely differing results. This is especially troublesome in partially ionized plasmas used, for instance, in the semiconductor industry, since no existing theory adequately treats the case when there are a few collisions between ions and neutral atoms. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: AIP Advances

سال: 2023

ISSN: ['2158-3226']

DOI: https://doi.org/10.1063/5.0146388