Two Prism Critical Angle Refractometry with Attenuating Media
نویسندگان
چکیده
We present a concept that enables the determination of complex refractive index attenuating media from two critical angles, measured sequentially at interfaces between single sample and different prisms. The proposed method is general in it applies with s p polarisation states, thus suited for characterisation isotropic as well anisotropic media. Uncertainty analysis indicates relative error real (imaginary) can be less than 10?4 (in order 10%), respectively.
منابع مشابه
Quartz-Enhanced Photoacoustic Spectroscopy with Right-Angle Prism
A right-angle prism was used to enhance the acoustic signal of a quartz-enhanced photoacoustic spectroscopy (QEPAS) system. The incident laser beam was parallelly inverted by the right-angle prism and passed through the gap between two tuning fork prongs again to produce another acoustic excitation. Correspondingly, two pairs of rigid metal tubes were used as acoustic resonators with resonance ...
متن کاملCritical angle for electrically driven coalescence of two conical droplets.
Oppositely charged drops attract one another and, when the drops are sufficiently close, electrical stresses deform the leading edges of each drop into cones. We investigate whether or not the liquid cones coalesce immediately following contact. Using high-speed imaging, we find that the coalescence behavior depends on the cone angle, which we control by varying the drop size and the applied vo...
متن کاملA wide-angle electron grating bi-prism beam splitter
We demonstrate a wide-angle electron beam splitter capable of producing 1 cm beam separation at the detection plane. The beam splitter utilizes a nanofabricated periodic grating in combination with a bi-prism element. In contrast to devices utilizing only bi-prism elements, the use of the periodic grating causes amplitude, and not wavefront, splitting. Even at maximum separation, beam profiles ...
متن کامل[Association between phase angle, PRISM I and sepsis severity].
BACKGROUND AND OBJECTIVES Phase angle (PA) is the difference between voltage and current and can be used as an indicator of body cell mass. Clinical studies show that low phase angle is associated with morbidity and mortality of critical patients. The purpose of this study was to know the relation between phase angle and the Pediatric Risk of Mortality I (PRISM I) score, associating this score ...
متن کاملQuantitative diffusion and swelling kinetic measurements using large-angle interferometric refractometry.
The uptake and release of sorbates into films and coatings is typically accompanied by changes of the films' refractive index and thickness. We provide a comprehensive model to calculate the concentration of the sorbate from the average refractive index and the film thickness, and validate the model experimentally. The mass fraction of the analyte partitioned into a film is described quantitati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Instruments
سال: 2022
ISSN: ['2410-390X']
DOI: https://doi.org/10.3390/instruments6030021