Unbalanced and Reactive Currents Compensation in Three-Phase Four-Wire Sinusoidal Power Systems

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Compensation of Unbalanced Three Phase Currents in a Transmission line using Distributed Power Flow Controller

Distributed Power Flow Controller is a new device within the family of FACTS. The DPFC has the same control capability as the UPFC, but with much lower cost and higher reliability. This paper addresses one of the applications of the DPFC namely compensation of unbalanced currents in transmission systems. Since the series converters of the DPFC are single phase, the DPFC can compensate both acti...

متن کامل

Implementation of Instantaneous Reactive Power Theory for Current Harmonic Reduction and Reactive Power Compensation in Three Phase Four Wire Power System

Most of the pollution issues created in power systems are due to the non-linear characteristics and fast switching of power electronic equipment. Power quality issues are becoming stronger because sensitive equipment will be more sensitive for market competition reasons, equipment will continue polluting the system more and more due to cost increase caused by the built-in compensation and somet...

متن کامل

Pi, Fuzzy Logic Controlled Shunt Active Power Filter for Three-phase Four-wire Systems with Balanced, Unbalanced and Variable Loads

This paper presents a fuzzy logic, PI controlled shunt active power filter used to compensate for harmonic distortion in three-phase four-wire systems. The shunt active filter employs a simple method for the calculation of the reference compensation current based on Fast Fourier Transform. The presented Shunt Active Power filter is able to operate in balanced, unbalanced and Variable load condi...

متن کامل

Application of Generalized Instantaneous Reactive Power Theory for Three-Phase Four-Wire System

Abstract—in this paper a concept of generalized theory of instantaneous imaginary power is proposed for a three-phase four-wire system. Unlike instantaneous reactive power theory in which a complex mathematical transformation is used for controlling action of shunt active power filters. The proposed control strategy is simple and further to reduced its complexity the line current vector is deco...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Applied Sciences

سال: 2020

ISSN: 2076-3417

DOI: 10.3390/app10051764