Urea sensor based on ion sensitive field effect transistor coated with cross-linked urease-albumin membrane.

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of an Ion Sensitive Field Effect Transistor Based Urea Biosensor with Solid State Reference Systems

Ion sensitive field-effect transistor (ISFET) based urease biosensors with solid state reference systems for single-ended and two-ended differential readout electronics were investigated. The sensing membranes of the biosensors were fabricated with urease immobilized in a conducting polymer-based matrix. The responses of 12.9∼198.1 mV for the urea concentrations of 8∼240 mg/dL reveal that the a...

متن کامل

Ion-sensitive field effect transistor as a pH sensor.

In this work, both the static and dynamic behaviors as well as the signal read-out circuits of ISFETs were studied. The standard NMOS structure in conjunction with the insulator-electrolyte capacitor was used to model the ISFET under study. The site-binding theory was incorporated to describe the chemistry occurring at the insulator/electrolyte interface. The mechanism of the threshold voltage ...

متن کامل

Potassium Ion-Sensitive Field Effect Transistor

was readily constructed by simple modification of a common FID hydrocarbon monitor, with addition of a commercially available valve oven, switching valve, and timer. This system, except for the adjusted response time, had virtually the same operating specifications as the original hydrocarbon analyzer. Short-term studies indicated the system was practical, reliable, and accurate. Air-monitoring...

متن کامل

fabrication of new ion sensitive field effect transistors (isfet) based on modification of junction-fet for analysis of hydronium, potassium and hydrazinium ions

a novel and ultra low cost isfet electrode and measurement system was designed for isfet application and detection of hydronium, hydrazinium and potassium ions. also, a measuring setup containing appropriate circuits, suitable analyzer (advantech board), de noise reduction elements, cooling system and pc was used for controlling the isfet electrode and various characteristic measurements. the t...

Determination of Atropine in Injection with β-Cyclodextrin Modified Ion Sensitive Field Effect Transistor Sensor

A new atropine drug-FET sensor, which was made of an ISFET (ion sensitive field effect transistor) and a drug sensitive membrane prepared by adding electric active matter to a β-cyclodextrin solution, was developed. The pH influence, selectivity, response curve, reproducibility, stability, response time and life of this sensor were investigated. A preliminary application of the sensor was discu...