Utilization of gradient front in liquid phase chromatography

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High speed gradient elution reversed-phase liquid chromatography.

A major disadvantage of gradient elution in terms of speed results from the need to adequately re-equilibrate the column. This work distinguishes two states of re-equilibration: (1) run-to-run repeatability and (2) full equilibration. We find that excellent repeatability (+/-0.002 min in retention time) is achieved with at most 2 column volumes of re-equilibration whereas full equilibration can...

متن کامل

EVALUATION OF THE USE OF ANIONIC/ NONIONIC MIXED MICELLES IN REVERSED PHASE LIQUID CHROMATOGRAPHY OF CHLOROPHENOLS

The use of aqueous mixed micellar system consisting of sodium dodecyl sulfate (SDS) and polyoxyethylene (23) dodecanol (Brij-35) as the mobile phase in reversed-phase liquid chromatography was studied. A group of chlorophenols was used as the test mixture. Adding organic modifier to the system showed that the use of low concentrations of organic additives improves efficiency in SDS/Brij-35 mixe...

متن کامل

Limits of multi-linear gradient optimisation in reversed-phase liquid chromatography.

The concept of limiting peak purity was applied to quantify the degree of completion of the separation capability of a chromatographic system using multi-linear gradients. The objective was to check whether the complexity of a gradient program deserves be increased to enhance resolution by inserting more linear segments, or on the contrary, no significant improvements can be expected under more...

متن کامل

New approach to linear gradient elution used for optimisation in reversed-phase liquid chromatography.

A new mathematical treatment concerning the gradient elution in reversed-phase liquid chromatography when the volume fraction psi of an organic modifier in the water-organic mobile phase varies linearly with time is presented. The experimental ln k versus psi curve, where k is the retention factor under isocratic conditions in a binary mobile phase, is subdivided into a finite number of linear ...

متن کامل

Selectivity Optimization with Commercial Coupled Columns by Gradient Stationary Phase Optimized Selectivity Liquid Chromatography

In previous studies stationary phase optimized selectivity liquid chromatography (SOSLC) has been already proved as a promising technique to optimize the selectivity of a given separation [1, 2]. By combination of different stationary phases, SOSLC offers excellent possibilities for method development under both isocratic and linear gradient conditions. However, the so far available commercial ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: BUNSEKI KAGAKU

سال: 1968

ISSN: 0525-1931

DOI: 10.2116/bunsekikagaku.17.1416