Validated air handling unit model using indirect evaporative cooling
نویسندگان
چکیده
منابع مشابه
Cooling output optimization of an air handling unit
A data-driven optimization approach for minimization of the cooling output of an air handling unit (AHU) is presented. The models used in this research are built with data mining algorithms. The performance of dynamic models build by four different data mining algorithms is studied. A model extracted by a neural network is selected for identifying the functional mapping between specific outputs...
متن کاملAn analytical model for evaporative cooling
We have developed an analytical model for evaporative cooling [1]. By simulating evaporation as a sequence of discrete steps, we could predict the time dependence of all important parameters such as temperature, density, elastic collision rate. By incorporating trap loss due to background gas collisions into our model we derived the threshold conditions for “run-away” evaporation. This is chara...
متن کاملEvaluation of Evaporative Cooling for Heat Transfer in the Condenser of Window-Air Conditioners
There is a demand for reduced power consumption in the vapor compression refrigeration cycle. Coefficient of performance of window-air conditioners considerably decreases and power consumption increases under very hot conditions. These problems have encouragecl studies aimed at improving the performance of window-air-conditioners by enhancing the heat transfer rate in the condenser. In this ar...
متن کاملOperating Energy Savings of a Liquid Desiccant and Evaporative Cooling-Assisted Air-Handling System in Marine Applications
The aim of this study is to analyze the operating energy savings of a liquid desiccant and an indirect and direct evaporative cooling-assisted 100% outdoor air system (LD-IDECOAS) for marine applications. The LD-IDECOAS comprises a liquid desiccant (LD) unit and indirect and direct evaporative coolers (IEC and DEC) to meet the target supply air (SA) conditions. In this study, seawater was used ...
متن کاملEvaluation of Evaporative Cooling for Heat Transfer in the Condenser of Window-Air Conditioners
There is a demand for reduced power consumption in the vapor compression refrigeration cycle. Coefficient of performance of window-air conditioners considerably decreases and power consumption increases under very hot conditions. These problems have encouragecl studies aimed at improving the performance of window-air-conditioners by enhancing the heat transfer rate in the condenser. In this ar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Building Performance Simulation
سال: 2017
ISSN: 1940-1493,1940-1507
DOI: 10.1080/19401493.2016.1273391