Validation of Pinnacle treatment planning system for use with Novalis delivery unit
نویسندگان
چکیده
منابع مشابه
Validation of Pinnacle treatment planning system for use with Novalis delivery unit
For an institution that already owns the licenses, it is economically advantageous and technically feasible to use Pinnacle TPS (Philips Radiation Oncology Systems, Fitchburg, WI) with the BrainLab Novalis delivery system (BrainLAB A.G., Heimstetten, Germany). This takes advantage of the improved accuracy of the convolution algorithm in the presence of heterogeneities compared with the pencil b...
متن کاملEvaluation of treatment planning system monitor unit calculations for three intensity modulated radiotherapy delivery techniques
Background: We have validated the monitor unit calculations from a commercially available treatment planning system (TPS) for three intensity modulated radiotherapy (IMRT) planning techniques for tangential breast irradiation by using ionization chamber measurements. Materials and Methods: Treatment plans were generated for forty-two breast patients by a forward planned field in field ...
متن کاملValidation of treatment planning system using simulation PRIMO code.
Introduction: In radiation therapy, in order to double-check the dosimetric results of the main treatment planning system (TPS), a distinct TPS, with few capacitances in terms of contouring and a variety of dose calculation algorithms is used. This system has the capability to double check the planification and the accurate prediction of dose distribution in order to be ensured...
متن کاملevaluation of treatment planning system monitor unit calculations for three intensity modulated radiotherapy delivery techniques
background: we have validated the monitor unit calculations from a commercially available treatment planning system (tps) for three intensity modulated radiotherapy (imrt) planning techniques for tangential breast irradiation by using ionization chamber measurements. materials and methods: treatment plans were generated for forty-two breast patients by a forward planned field in field technique...
متن کاملCommissioning compensator‐based IMRT on the Pinnacle treatment planning system
We present a systematic approach to commissioning of the compensator-based IMRT in Pinnacle treatment planning system for commercially manufactured brass compensators. Some model parameters for the beams modulated by the variable-thickness compensators can only be associated with a single compensator thickness. To intelligently choose that thickness for beam modeling, we empirically determined ...