Wear Analysis in THA Utilizing Oxidized Zirconium and Crosslinked Polyethylene
نویسندگان
چکیده
منابع مشابه
Wear of highly crosslinked polyethylene acetabular components
BACKGROUND AND PURPOSE Wear rates of highly crosslinked polyethylene (XLPE) acetabular components have varied considerably between different published studies. This variation is in part due to the different techniques used to measure wear and to the errors inherent in measuring the relatively low amounts of wear in XLPE bearings. We undertook a scoping review of studies that have examined the i...
متن کاملDo oxidized zirconium femoral heads reduce polyethylene wear in cemented THAs? A blinded randomized clinical trial.
BACKGROUND Charnley low-friction torque total hip arthroplasty (THA) remains the gold standard in THA. The main cause for failure is wear of the socket. Highly crosslinked polyethylene (HXLPE) has been associated with reduced wear rates. Also, oxidized zirconium has shown in vitro reduced wear rates. However, to our knowledge, there are no data comparing oxidized zirconium femoral heads with me...
متن کاملCORR Insights(®): oxidized zirconium head on crosslinked polyethylene liner in total hip arthroplasty: a 7- to 12-year in vivo comparative wear study.
BACKGROUND Osteolysis resulting from wear debris production from the bearing surfaces is a major factor limiting long-term survival of hip implants. Oxidized zirconium head on crosslinked polyethylene (XLPE) is a modern bearing coupling. However, midterm in vivo wear data of this coupling are not known. QUESTIONS/PURPOSES The purpose of this study was to investigate in vivo whether the combin...
متن کاملExtensive Bone Reaction From Catastrophic Oxidized Zirconium Wear.
The use of alternative bearing surfaces for total hip arthroplasty has become popular to minimize wear and increase longevity, especially in young patients. Oxidized zirconium (Oxinium; Smith & Nephew, Memphis, Tennessee) femoral heads were introduced in the past decade for use in total hip arthroplasty. The advantages of oxidized zirconium include less risk of fracture compared with traditiona...
متن کاملAnalysis of polyethylene wear in plain radiographs
BACKGROUND AND PURPOSE Two-dimensional computerized radiographic techniques are frequently used to measure in vivo polyethylene (PE) wear after total hip arthroplasty (THA), and several variables in the clinical set-up may influence the amount of wear that is measured. We compared the repeatability and concurrent validity of linear PE wear on plain radiographs using the same software but a diff...