percutaneous liver biopsies guided with ultrasonography: a case series

نویسندگان

emin cakmakci department of radiology, sisli etfal training and research hospital, istanbul, turkey; department of radiology, sisli etfal training and research hospital, istanbul, turkey. tel: +90-5059436888, fax: +90-2123735014

kosti can caliskan department of radiology, sisli etfal training and research hospital, istanbul, turkey

omer naci tabakci department of radiology, sisli etfal training and research hospital, istanbul, turkey

mehmet tahtabasi department of radiology, sisli etfal training and research hospital, istanbul, turkey

چکیده

conclusion according to the results of our series, percutaneous liver biopsy using the tru-cut biopsy gun guided by ultrasonography can be performed safely. we resolve that routine ultrasound of the puncture site is a quick, effective and safe procedure. the complication rate is very low. the us-assisted percutaneous liver biopsy should be used for all cases. results a total of 1018 patients were referred to our radiology department. most of the patients had hepatitis b (60.6%). the biopsy specimens were recorded and sent to our pathology department for histopathological examination. patients and methods in our retrospective study, we evaluated ultrasound-assisted needle biopsies that were performed in outpatients from october 2006 to july 2010. the liver biopsies were performed following one-night fasting using the tru-cut biopsy gun (18-20 gauge) after marking the best seen and hypovascular part of the liver, distant enough from the adjacent organs. background although liver biopsy is an easy procedure for hospitalized patients and outpatients, some complications may occur. objectives to evaluate the efficiency, complications, safety and clinicopathological utility of ultrasonographic-guided percutaneous liver biopsy in diffuse liver disease.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous Liver Biopsies Guided with Ultrasonography: A Case Series

BACKGROUND Although liver biopsy is an easy procedure for hospitalized patients and outpatients, some complications may occur. OBJECTIVES To evaluate the efficiency, complications, safety and clinicopathological utility of ultrasonographic-guided percutaneous liver biopsy in diffuse liver disease. PATIENTS AND METHODS In our retrospective study, we evaluated ultrasound-assisted needle biops...

متن کامل

Safety profile of paediatric percutaneous ultrasonography-guided renal biopsies.

INTRODUCTION Renal biopsy (RB) is a decisive diagnostic procedure for patients with renal disease. Our aim was to assess the safety of RB and the prevalence of associated clinical complications. METHODS A total of 166 RBs were performed in 164 children (88 boys, 76 girls) in East Bohemia in 1997-2007. The mean age of the children was 12.9 +/- 4.1 years. All RBs were performed by a single cons...

متن کامل

Image - guided percutaneous breast biopsies

Diagnosis of breast cancer at its earliest stage affords women the best prognosis. The role of the breast imager has evolved from cancer screening and detection to now include diagnosis and management with the widespread adoption of image-guided core biopsy. This article will briefly discuss the current imageguided biopsy techniques for the diagnosis of suspicious breast findings, specifically,...

متن کامل

Complications and risk factors of a large series of percutaneous liver biopsies in patients with liver transplantation or liver disease.

OBJECTIVE   Liver biopsy is a very important investigation in Hepatology. The aim of this retrospective study was to assess the prevalence of complications after Percutaneous Liver Biopsy (PLB), performed in two groups of patients with liver transplantation or with liver disease. We compared our results with those most representative of the literature and discussed about indications, advantages...

متن کامل

Osteoid osteoma treated with computed tomography-guided percutaneous radiofrequency ablation: a case series.

The nidi of osteoid osteoma are small and difficult to identify precisely; this can necessitate substantial resection of the surrounding normal bone. We applied percutaneous, image-guided radiofrequency ablation to treat 5 patients with osteoid osteoma. The precise location of each nidus was determined using a 3-mm-thick spiral computed tomographic scan. The most appropriate needle pathway was ...

متن کامل

Ultrasound guided percutaneous biopsies of suspected mediastinal lesions.

Realtime ultrasonography with general purpose sector transducer was used to guide 87 percutaneous biopsies on 82 patients with lesions suspected to be mediastinal masses on plain chest radiographs. In seven patients who had dyspnea the biopsies were done in erect or semi-erect sitting positions. Definitive diagnosis was obtained from 66 lesions (80.5%) where 46 (70.0%) were mediastinal and the ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of radiology

جلد ۱۰، شماره ۳، صفحات ۱۸۲-۱۸۴

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023