optimization of solid phase micro-extraction (spme) for monitoring occupational exposure to ethyl benzene

نویسندگان

حمیدرضا حیدری

hr heidari qom university of medical sciencesدانشگاه علوم پزشکی قم سید جمال الدین شاه طاهری

sj shahtaheri tehran university of medical sciencesدانشگاه علوم پزشکی تهران محمود علیمحمدی

m alimohammadi tehran university of medical sciencesدانشگاه علوم پزشکی تهران عباس رحیمی فروشانی

a rahimi-froshani tehran university of medical sciencesدانشگاه علوم پزشکی تهران فریده گلبابایی

چکیده

background and objectives: analytical methods for volatile organic compounds (vocs) in different samples need extraction of compounds, by applying hazardous solvents. solid phase micro-extraction (spme) is a solvent-free equilibrium extraction method, in which proper calibration can allow quantitative determinations of vocs at a very good sensitivity without the use of any organic solvent. vocs are generally present in urine only at trace levels, therefore, a sensitive procedure is needed for their trace determinations. throughout this study, headspace solid phase micro-extraction (hs-spme) was followed by gc-fid for ethyl benzene in spiked urine was optimized. methods: in this study, the parameters influencing spme and gas chromatography of ethyl benzene, including extraction time, temperature, desorption temperature, desorption time, salt addition, sample ph, sample volume and sample agitation were investigated. results: extraction procedure was performed at 30°c for 6 min, using 0.2 gml-1 of nacl in the sample solution. the sample volume and sample ph were optimized at 5 ml and 7 (neutral ph), respectively. desorption of the ethyl benzene was carried out for 60 sec. at 250°c. the method was also validated with three different spiked urine samples and illustrated an appropriate reproducibility over six consecutive days as well as six within-day experiments. during this investigation, parameters of accuracy, linearity, and detection limits of the procedure were also evaluated. conclusion: the developed method of hs- spme-gc-fid proved to be a simple, convenient, and practical procedure, and was successfully used for measuring of ethyl benzene in spiked urine.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Solid Phase Extraction for 1-Hydroxypyrene as a Biomarker of Occupational Exposure to PAHs Prior to High Performance Liquid Chromatography

Urinary 1-hydroxypyrene is frequently used as a major metabolite and biological indicator of the overall exposure to polycyclic aromatic hydrocarbons. In this study, solid phase extraction was appropriately conditioned with regard to sample pH, sample concentration, loading flow rate, elution solvent, washing solvent, sample volume and sorbent mass. Octadecyl silica cartridge (C<su...

متن کامل

Solid Phase Extraction for Monitoring of Occupational Exposure to Cr (III)

Chromium is an important constituent widely used in different industrial processes for production of various synthetic materials. For evaluation of workers' exposure to trace toxic metal of Cr (III), environmental and biological monitoring are essential processes, in which, preparation of samples is one of the most time-consuming and error-prone aspects prior to analysis. The use of solid-phase...

متن کامل

solid phase extraction for 1-hydroxypyrene as a biomarker of occupational exposure to pahs prior to high performance liquid chromatography

urinary 1-hydroxypyrene is frequently used as a major metabolite and biological indicator of the overall exposure to polycyclic aromatic hydrocarbons. in this study, solid phase extraction was appropriately conditioned with regard to sample ph, sample concentration, loading flow rate, elution solvent, washing solvent, sample volume and sorbent mass. octadecyl silica cartridge (c18) was used as ...

متن کامل

Extraction and analysis of polycyclic aromatic hydrocarbons (PAHs) by solid phase micro-extraction/supercritical fluid chromatography (SPME/SFC)

Solid phase micro-extraction (SPME) is a clean and simple pre-concentration method. Previously used for trace analysis of volatil compounds, the use of SPME was extended to non volatil molecules with the development of an SPME /HPLC interface. This new interface allows the extraction and the analyses of high molecular weight compounds found in aqueous samples. Since supercritical fluid chromato...

متن کامل

Occupational exposure to benzene in China.

Of a total of 528,729 workers exposed to benzene or benzene mixtures in China, 508,818 (96.23%) were examined. Altogether 2,676 cases of benzene poisoning were found, a prevalence of 0.15%. A higher prevalence of benzene poisoning was found in the cities of Hangjou, Hefei, Nanjing, Shenyang, and Xian. The geometric mean concentration of benzene in 50,255 workplaces was 18.1 mg/m3 but 64.6% of t...

متن کامل

N-octyl-modified magnetite NPs for optimization of solid phase extraction for trace analysis of phenytoin in real samples

objective: Phenytoin is an anti-seizure medication used to treat epilepsy, as well as to control arrhythmias (irregular heartbeat) and to treat migraine headaches and nerve pain. It is recommended to determine the amount of this drug in the blood to control the seizure and prevent its toxicity. In the present study, a sensitive and simple procedure based on the dispersive solid phase extraction...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
مجله دانشگاه علوم پزشکی قم

جلد ۳، شماره ۲، صفحات ۵-۱۲

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023