inactivation of model viruses suspended in fresh frozen plasma using novel methylene blue based device.

نویسندگان

ameneh elikaei department of microbiology, faculty of biological science shahidbeheshti university gc,tehran, iran.

zohreh sharifi blood transfusion research center, high institute for research and education in transfusion medicine, tehran, iran.

seyed-masoud hosseini department of microbiology, faculty of biological science shahidbeheshti university gc,tehran, iran.

hamid latifi laser and plasma research institute, shahidbeheshti university, gc, tehran, iran.

چکیده

background and objective: there is a concern on safety of human fresh frozen plasma (ffp) as it is a source of some medicinal products. the possibility of transmission of blood-borne are reported often due to emerging viruses. there are some pathogen reduction technologies (prt) to inactivate viruses. methylene blue (mb) based method is one of them. the aim of this study was to examine new designated device to inactivate model viruses. materials and methods: four model viruses were used in this study:vesicular stomatitis virus (vsv), herpes simplex virus i (hsv-1), bovine viral diarrheavirus(bvdv) and polio virus.50% tissue culture infective dose (tcid 50) and reed-muench methods were used to titer the viruses. mb in two final concentration of 0.1 μm and 1 μm and illumination in about 627nm with red led (lamp emitting diode) for 15, 30, 45 and 60 minutes were used. three replicates employed for each experiments. results: 1μmconcentration of mb showed more effective than 0.1μmin all designed illumination period for inactivation of hsv, vsv and bvdv. this method also demonstrated best results for enveloped model viruses. the most log reduction for hsv, vsv and bvdv were6.28, 5.54 and 6.22, respectively. for hsv and bvdv inactivation, the best illumination period was 45 minutes. conclusion: model viruses showed sensitivity combination of mb and illumination using red leds. as results show this device could inactivate model viruses and reduce their titer very close to approved commercial devices, in compare.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inactivation of model viruses suspended in fresh frozen plasma using novel methylene blue based device

BACKGROUND AND OBJECTIVE There is a concern on safety of human Fresh Frozen Plasma (FFP) as it is a source of some medicinal products. The possibility of transmission of blood-borne are reported often due to emerging viruses. There are some Pathogen Reduction Technologies (PRT) to inactivate viruses. Methylene Blue (MB) based method is one of them. The aim of this study was to examine new desig...

متن کامل

The Effect of Methylene Blue in Combination with Red Visible Light on Model Viruses Inactivation and Coagulation Factors in Fresh Frozen Plasma

Background and Aims: Fresh Frozen Plasma (FFP) is one of blood components. The risk of transmission of viruses from blood components regardless selection of blood donors and screening donated blood still remains. There are several methods for viral inactivation. In this study methylene blue (MB) photo inactivation process was used for inactivating viruses. Materials and Methods: In this study M...

متن کامل

Methylene Blue Based Device for Pathogen Reduction in Human Plasma

Abstract Background Despite improvement in safety of plasma transfusion some virus transmission still remains a problem. So as World Health Organization (WHO) recommends, many countries developed Pathogen Reduction Technologies (PRT) to inactivate pathogens, in plasma components. The Methylene Blue (MB) based methods is one of the most universal one. The purpose of this research was, produce...

متن کامل

inactivation of model viruses and bacteria in human fresh frozen plasma using riboflavin and long wave ultraviolet rays

background and objectives: pathogen reduction technologies are among methods to eliminate transfusion transmitted infections. mirasol method using riboflavin in combination with ultraviolet rays is one of them. the aims of this study were to investigate the effectiveness of mirasol method to inactivate some model pathogens as well as examination of the sensitivity of plasma proteins after treat...

متن کامل

Methylene Blue Based Device for Pathogen Reduction in Human Plasma

BACKGROUND Despite improvement in safety of plasma transfusion some virus transmission still remains a problem. So as World Health Organization (WHO) recommends, many countries developed Pathogen Reduction Technologies (PRT) to inactivate pathogens, in plasma components. The Methylene Blue (MB) based methods is one of the most universal one. The purpose of this research was, produce a device th...

متن کامل

Inactivation of model viruses and bacteria in human fresh frozen plasma using riboflavin and long wave ultraviolet rays

BACKGROUND AND OBJECTIVES Pathogen reduction technologies are among methods to eliminate transfusion transmitted infections. Mirasol method using riboflavin in combination with ultraviolet rays is one of them. The aims of this study were to investigate the effectiveness of Mirasol method to inactivate some model pathogens as well as examination of the sensitivity of plasma proteins after treatm...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of microbiology

جلد ۶، شماره ۱، صفحات ۴۱-۴۵

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023