purpose : to compare visual quality in patients receiving alcon acrysof restor multifocal versus acrysof sa60at monofocal intraocular lenses (iol) methods : in this interventional study, patients with senile cataract undergoing surgery were enrolled. the age of the patients ranged between 40 and 85 years, and their potential preoperative vision was 20/30 or better. in all patients phacoemulsification was performed through a temporal 2.8 mm incision. postoperative visual acuity (va), refraction, and contrast sensitivity (with and without glare) tests were done at 1 and 3 months. a total of 101 eyes were evaluated. a multifocal iol was implanted in 52.5% of cases, and in the rest, a monofocal iol was used. results : at 3 months, the mean distant va without and with correction was 0.11 and 0.04 logmar, respectively, in the multifocal iol group, and 0.14 and 0.03 logmar, respectively, in the monofocal iol group (p>0.10). the near va without and with correction was 0.14 and 0.05 logmar, respectively, in the multifocal group and 0.22 and 0.04 logmar, respectively, in the monofocal iol group, statistically significantly better in the multifocal group (p=0.038). at 3 months after surgery, contrast sensitivity with and without glare showed statistically significant inter-group differences at 6, 12 and 18 cycles per degree (cpd), and at 6 and 12 cpd, respectively. these figures were higher in monofocal group. conclusion : use of multifocal iols in cataract surgery can restore near vision to some extent in addition to distant vision. contrast sensitivity in recipients of multifocal iols is lower than those with monofocal iols.   iranian journal of ophthalmology 200921(4):25-31 © 2009 by the iranian society of ophthalmology

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Visual acuity and contrast sensitivity: AcrySof ReSTOR apodized diffractive versus AcrySof SA60AT monofocal intraocular lenses.

PURPOSE To compare the visual acuity and contrast sensitivity in eyes with the AcrySof ReSTOR multifocal intraocular lens (IOL) (Alcon) and eyes with the monofocal AcrySof SA60AT IOL. SETTING Policlinico Umberto I, Department of Ophthalmology, Rome, and private clinical practice, Rome, Italy. METHODS One hundred eyes had phacoemulsification cataract extraction and implantation of a ReSTOR m...

متن کامل

Compared optical performances of multifocal and monofocal intraocular lenses (contrast sensitivity and dynamic visual acuity)

The functional results (contrast sensitivity and dynamic visual acuity) of 19 multifocal (3M design) and 14 all polymethylmethacrylate biconvex monofocal intraocular lenses (IOLs), 6 mm in optical diameter were compared. Best corrected visual acuity was > or = 8/10 (Monoyer chart) Parinaud 2 in all cases. Major differences of functional performance in favour of monofocal IOLs were found outside...

متن کامل

Visual performance of Acrysof ReSTOR compared with a monofocal intraocular lens following implantation in cataract surgery

The aim of this study was to compare the visual performance of Acrysof ReSTOR and Acrysof Natural intraocular lenses (IOLs) following cataract surgery. A randomized prospective study was performed in which 64 eyes (51 patients) were divided randomly into two groups. Monofocal IOLs (Acrysof Natural) were implanted into 34 eyes (27 patients) and multifocal IOLs (Acrysof ReSTOR) were implanted int...

متن کامل

Wavefront aberrations in eyes with Acrysof monofocal intraocular lenses.

PURPOSE To characterize and measure the ocular aberrations in eyes implanted with monofocal intraocular lenses (IOLs) and to study any correlation between postoperative aberrations and surgical factors. METHODS A Tscherning aberroscope was used to measure the wavefront aberrations of 62 eyes that had undergone phacoemulsification with the implantation of foldable monofocal Acrysof MA60BM IOLs...

متن کامل

Ocular wavefront analysis and contrast sensitivity in eyes implanted with AcrySof IQ or AcrySof Natural intraocular lenses.

PURPOSE This study aimed to compare ocular wavefront aberrations for pupil diameters of 4 mm and 6 mm, and contrast sensitivity, in eyes with AcrySof IQ and AcrySof Natural intraocular lenses (IOLs). METHODS Sixty eyes of 60 patients were enrolled in this prospective randomized study. After phacoemulsification the eyes received either AcrySof IQ SN60WF or AcrySof Natural SN60AT IOLs. One mont...

متن کامل

Postoperative wavefront analysis and contrast sensitivity of a multifocal apodized diffractive IOL (ReSTOR) and three monofocal IOLs.

PURPOSE To compare visual acuity, total and high order wavefront aberrations (coma, spherical aberration, and other terms of high order aberration), and contrast sensitivity in 105 eyes implanted with 4 different types of intraocular lenses (IOLs) (1 multifocal apodized diffractive IOL and 3 monofocal IOLs). METHODS A prospective study comparing four types of IOLs (Alcon ReSTOR [50 eyes], Alc...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of current ophthalmology

جلد ۲۱، شماره ۴، صفحات ۲۵-۳۱

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023