Collimator effects in proton planning
نویسنده
چکیده
The present paper pertains to corrections which are due to the presence of beam-limiting and beam-shaping devices in a proton-treatment plan. Two types of corrections are considered: those which are due to the nonzero thickness of such devices (geometrical effects) and those relating to the scattering of beam particles off their material. The application of these two types of corrections is greatly facilitated by decomposing the physical effects (i.e., the contribution to the fluence) of twodimensional objects (i.e., of the apertures of the devices) into one-dimensional, easilycalculable contributions. To minimise the time requirements in the derivation of the scattering corrections, a two-step process is introduced. The first step occurs at beamconfiguration time and comprises the analysis of half-block fluence measurements; subsequently, a number of Monte-Carlo runs lead to the determination of the parameters of a convenient parameterisation of the relevant fluence contributions. The second step involves (at planning time) the reconstruction of the parameters (which are used in the description of the scattering contributions) via simple interpolations, performed on the results obtained at machine-configuration time. Given the lack of dedicated data, the validation of the method is currently based on the reproduction of the parts of the half-block fluence measurements (i.e., of the data used as input at configuration time) which had been removed from the database prior to processing; it is shown that the inclusion of the scattering effects leads to substantial improvement in the reproduction of the experimental data. A simple example of the block-relating corrections has been included in this study; the contributions from the block-thickness and block-scattering effects have been presented separately in the case of a simple water phantom. In this example, the maximal contribution of the block-relating effects amounts to a few percent of the prescribed dose. PACS numbers: 87.55.Gh, 87.55.kh, 87.56.jk, 87.56.nk
منابع مشابه
An empirical model for calculation of the collimator contamination dose in therapeutic proton beams.
Collimators are used as lateral beam shaping devices in proton therapy with passive scattering beam lines. The dose contamination due to collimator scattering can be as high as 10% of the maximum dose and influences calculation of the output factor or monitor units (MU). To date, commercial treatment planning systems generally use a zero-thickness collimator approximation ignoring edge scatteri...
متن کاملThe Dosimetric Effects of Different Multileaf Collimator Widths on Physical Dose Distributions
Introduction: Geometric changes in the multileaf collimator (MLC) led to dosimetric considerations in intensity-modulated radiation therapy (IMRT) due to the number and size of the pixels in the intensity map, which are determined by the MLC leaf width. In this study, we evaluated the dosimetric effects of different MLC widths on physical dose distributions for IMRT plans. Materials and Method...
متن کاملReduction of the secondary neutron dose in passively scattered proton radiotherapy, using an optimized pre-collimator/collimator.
Proton radiotherapy represents a potential major advance in cancer therapy. Most current proton beams are spread out to cover the tumor using passive scattering and collimation, resulting in an extra whole-body high-energy neutron dose, primarily from proton interactions with the final collimator. There is considerable uncertainty as to the carcinogenic potential of low doses of high-energy neu...
متن کاملDerivation and validation of a sensitivity formula for knife-edge slit gamma camera: A theoretical and Monte Carlo simulation study
Introduction: Gamma cameras are proposed for online range verification and treatment monitoring in proton therapy. An Analytical formula was derived and validated for sensitivity of a slit collimator based on the photon fluence concept. Methods: Fluence formulation was generalized for photons distribution function and solved for high-energy point sources. The...
متن کاملOptimization of collimator parameters to reduce rectal dose in intensity-modulated prostate treatment planning.
The inability to avoid rectal wall irradiation has been a limiting factor in prostate cancer treatment planning. Treatment planners must not only consider the maximum dose that the rectum receives throughout a course of treatment, but also the dose that any volume of the rectum receives. As treatment planning techniques have evolved and prescription doses have escalated, limitations of rectal d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008