Carotid Wallstent placement difficulties encountered in carotid artery stenting

نویسندگان

  • Kaoru Myouchin
  • Katsutoshi Takayama
  • Toshiaki Taoka
  • Hiroyuki Nakagawa
  • Takeshi Wada
  • Masahiko Sakamoto
  • Satoru Iwasaki
  • Shinichiro Kurokawa
  • Kimihiko Kichikawa
چکیده

PURPOSE The present study aimed to identify the types of curved lesions that are difficult to place Carotid Wallstent (CWS). MATERIALS AND METHODS The study targeted 31 consecutive carotid artery (CA) stenosis underwent carotid artery stenting using CWS. CWS placement success rate, stenosis location, lesion tortuosity, and relationship with stent placement failures were investigated. Lesion tortuosity was defined as the angle formed by 2 tangential lines between internal CA and common CA from the inflection point (IP) was defined as the center of lesion curvature. Stenosed lesions were classified into type A or B. Type A was defined as if the distal end of the stenosis was located proximal to the IP at a distance ≥0.5 of a vertebral body based on the posterior height of the 3rd vertebral body, otherwise was type B. RESULTS The stent placement success rate was 93.5% (29/31). The 2 unsuccessfully stented lesions, both lesions were significantly different from other lesions by having a lesion tortuosity less than 90° and by belonging to type B. CONCLUSION Since CWS placement is difficult in patients with CA stenosis located close to the IP at a lesion tortuosity ≤90°, open-cell stents should be considered as an alternative.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ANGIOPLASTY AND STENTING OF CAROTID ARTERY STENOSIS WITH EMBOLIC PROTECTION DEVICES

Background: Carotid artery stenting (CAS) has recently been recommended as an alternative to carotid endarterectomy (CEA) by some clinicians. Objective: This study was designed to evaluate the success rate and in-hospital and 30-day adverse events in our first experiences in Iran for CAS with protection devices, to document our results and guide further use of CAS. Methods: From December 2...

متن کامل

Carotid angioplasty and stenting in a patient with high grade stenosis of Internal Carotid Artery associated with both vertebral arteries and contralateral carotid occlusion

Severe internal carotid artery (ICA) stenosis is a common cause of cerebrovascular accident (CVA) in middle-aged patients. Contralateral carotid occlusion (CCO) in patients with severe ICA stenosis is associated with high risk of CVA. Carotid endarterectomy (CEA) is associated with more complications in patients with CCO than those without CCO. In this study, we present the case of a 61-year-ol...

متن کامل

Intravascular Ultrasound for Intracranial and Extracranial Carotid Artery Stent Placement

Intravascular ultrasound (IVUS) can provide valuable information regarding endoluminal morphology. We present the first description of IVUS-guided intracranial and extracranial carotid artery stent placement for arterial dissection. A 41-year-old female with a sudden-onset headache and blurred vision underwent a computed tomography (CT) angiogram imaging that revealed bilateral carotid artery d...

متن کامل

Carotid artery stenting with distal protection using the carotid wallstent and filterwire neuroprotection: single-center experience of 380 cases with midterm outcomes.

Emerging data have supported the clinical efficacy of carotid artery stenting (CAS) in stroke prevention in high-risk surgical patients. This study was performed to evaluate the midterm clinical outcome of CAS using the Carotid Wallstent and FilterWire distal protection (both Boston Scientific, Natick, MA) at an academic institution. Risk factors for in-stent restenosis (ISR) were also analyzed...

متن کامل

A rare complication of carotid artery stenting: displacement of marker ring causing locking of stent and incomplete stent expansion.

We present a rare case of a complication of placement of a carotid artery stent represented by partial opening of a carotid Wallstent caused by displacement of its metal ring marker, which thus hindered complete expansion of the stent. An intraluminally locked carotid stent necessitated referral of the patient for urgent carotid endarterectomy. A possible reason of this unusual complication can...

متن کامل