Whole-heart four-dimensional flow can be acquired with preserved quality without respiratory gating, facilitating clinical use: a head-to-head comparison
نویسندگان
چکیده
BACKGROUND Respiratory gating is often used in 4D-flow acquisition to reduce motion artifacts. However, gating increases scan time. The aim of this study was to investigate if respiratory gating can be excluded from 4D flow acquisitions without affecting quantitative intracardiac parameters. METHODS Eight volunteers underwent CMR at 1.5 T with a 5-channel coil (5ch). Imaging included 2D flow measurements and whole-heart 4D flow with and without respiratory gating (Resp(+), Resp(-)). Stroke volume (SV), particle-trace volumes, kinetic energy, and vortex-ring volume were obtained from 4D flow-data. These parameters were compared between 5ch Resp(+) and 5ch Resp(-). In addition, 20 patients with heart failure were scanned using a 32-channel coil (32ch), and particle-trace volumes were compared to planimetric SV. Paired comparisons were performed using Wilcoxon's test and correlation analysis using Pearson r. Agreement was assessed as bias±SD. RESULTS Stroke volume from 4D flow was lower compared to 2D flow both with and without respiratory gating (5ch Resp(+) 88±18 vs 97±24.0, p=0.001; 5ch Resp(-) 86±16 vs 97.1±22.7, p<0.01). There was a good correlation between Resp(+) and Resp(-) for particle-trace derived volumes (R2=0.82, 0.2±9.4 ml), mean kinetic energy (R2=0.86, 0.07±0.21 mJ), peak kinetic energy (R2=0.88, 0.14±0.77 mJ), and vortex-ring volume (R2=0.70, -2.5±9.4 ml). Furthermore, good correlation was found between particle-trace volume and planimetric SV in patients for 32ch Resp(-) (R2=0.62, -4.2±17.6 ml) and in healthy volunteers for 5ch Resp(+) (R2=0.89, -11±7 ml), and 5ch Resp(-) (R2=0.93, -7.5±5.4 ml), Average scan duration for Resp(-) was shorter compared to Resp(+) (27±9 min vs 61±19 min, p<0.05). CONCLUSIONS Whole-heart 4D flow can be acquired with preserved quantitative results without respiratory gating, facilitating clinical use.
منابع مشابه
Whole-heart 4D flow can be acquired with preserved quality without respiratory gating facilitating clinical use
Results Stroke volume from 4D flow was lower compared to 2D flow (5ch Resp(+) 86.9±17.0 vs 97.1±22.7, p=0.001; 5ch Resp(-) 83.9±16.0 vs 97.1±22.7, p<0.001), with no difference in bias (-10.3±11.0% vs -13.8±11.9%, p=0.16) (Figure 1). There was a good correlation between Resp(+) and Resp(-) for particle-trace derived volumes (R=0.82, 1.6±12.4%), mean kinetic energy (R=0.86, -4.3±12.4%), peak kine...
متن کاملWhole-heart cine MRI using real-time respiratory self-gating.
Two-dimensional (2D) breath-hold cine MRI is used to assess cardiac anatomy and function. However, this technique requires cooperation from the patient, and in some cases the scan planning is complicated. Isotropic nonangulated three-dimensional (3D) cardiac MR can overcome some of these problems because it requires minimal planning and can be reformatted in any plane. However, current methods,...
متن کاملDeveloping Persian version of Sensory Gating Inventory (SGI): Validity and Reliability
Introduction: Sensory Gating Inventory (SGI) measures behavioral aspects of Sensory Gating (SG). It is a filtering mechanism of brain that prevents irrelevant sensory inputs from entering into higher cortex information processing. It modifies sensitivity to sensory stimuli. Abnormal SG leads to overloading of information into cortex and brain dysfunction. Electrophysiological techniques cannot ...
متن کاملLow kilovolt “prospective ECG-triggering” vs. “retrospective ECG-gating” coronary CTA: comparison of image quality and radiation dose
Background: To compare image quality and radiation doses of low kilovolt (kV) “prospective ECG-triggering” (PT) and standard “retrospective ECG-gating” (RG) coronary computed tomography (CT) angiography. Materials and Methods: A total of 101 consecutive patients (76 males, 25 females; mean age: 55.44 ± 8.28 years) with low-to-intermediate risk status for coronary artery disease and with a body ...
متن کاملComparison of radiotherapy techniques to reduce hematologic toxicity in whole pelvic radiation therapy
Introduction: Concurrent chemoradiotherapy (CRT) is a standard treatment method for patients with carcinoma of cervix. Despite admirable therapeutic results, acute hematologic toxicity (HT) is common with this regimen. Many studies evaluate the relationship between the bone marrow dosimetric parameters and the severity of HT and result shown that the low dose of bone marrow wou...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 15 شماره
صفحات -
تاریخ انتشار 2015