Characterization of Solute Distribution Following Iontophoresis from a Micropipet

نویسندگان

  • Douglas C. Kirkpatrick
  • Martin A. Edwards
  • Paul A. Flowers
  • R. Mark Wightman
چکیده

Iontophoresis uses a current to eject solution from the tip of a barrel formed from a pulled glass capillary and has been employed as a method of drug delivery for neurochemical investigations. Much attention has been devoted to resolving perhaps the greatest limitation of iontophoresis, the inability to determine the concentration of substances delivered by ejections. To further address this issue, we evaluate the properties of typical ejections such as barrel solution velocity and its relation to the ejection current using an amperometric and liquid chromatographic approach. These properties were used to predict the concentration distribution of ejected solute that was then confirmed by fluorescence microscopy. Additionally, incorporation of oppositely charged fluorophores into the barrel investigated the role of migration on the mass transport of an ejected species. Results indicate that location relative to the barrel tip is the primary influence on the distribution of ejected species. At short distances (<100 μm), advection from electroosmotic transport of the barrel solution may significantly contribute to the distribution, but this effect can be minimized through the use of low to moderate ejection currents. However, as the distance from the source increases (>100 μm), even solute ejected using high currents exhibits diffusion-limited behavior. Lastly a time-dependent theoretical model was constructed and is used with experimental fluorescent profiles to demonstrate how iontophoresis can generate near-uniform concentration distributions near the ejection source.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Probabilistic Contaminant Source Identification in Water Distribution Infrastructure Systems

Large water distribution systems can be highly vulnerable to penetration of contaminant factors caused by different means including deliberate contamination injections. As contaminants quickly spread into a water distribution network, rapid characterization of the pollution source has a high measure of importance for early warning assessment and disaster management. In this paper, a methodology...

متن کامل

Investigating and Mathematical Correlation of the Presence Effect of Solute and Surfactant on Mean Drop size in a Mixer-Settler

In this paper, the effects of several factors such as surfactant concentration, solute concentration, impeller speed and holdup on the mean drop diameter ( ) during emulsification have been studied in a single-stage mixer-settler extractor. A video technique has been developed in order to measure drop size distribution in the mixing chamber using a digital camera. The results show decreases wi...

متن کامل

Synergistic Effect of Chemical Enhancer And Iontophoresis For Transdermal Delivery Of Nebivolol Hydrochloride

The aim of the present study was to develop and investigate the feasibility of delivering Nebivolol as a transdermal patch by iontophoresis. The passive and electrically assisted transdermal delivery of Nebivolol hydrochloride by iontophoresis will improve the therapeutic efficacy and overcome the difficulties raised in oral drug delivery. Because of its extensive hepatic metabolism and low dos...

متن کامل

مقایسه‌ی یونتوفورزیس با آب لوله‌کشی و نرمال سالین در درمان پرتعریقی اولیه: گزارش موردی

Idiopathic (primary) hyperhidrosis is defined as an excessive sweating with no clear cause and usually results in social, psychological, and professional disturbances. In this study, tap water and normal saline iontophoresis were used in a 21-year-old female suffering from severe idiopathic palmoplantar hyperhidrosis.The result of 8 sessions iontophoresis showed that tap water and norm...

متن کامل

Scanning electrochemical microscopy. 40. Voltammetric ion-selective micropipet electrodes for probing ion transfer at bilayer lipid membranes.

Voltammetric ion-selective micropipet electrodes for use in scanning electrochemical microscopy (SECM) for detection of potassium ion were fabricated. These used pulled borosilicate capillaries with tip orifice radii of 0.7-20 microm with silanized inner walls filled with a solution of 10 mM valinomycin and 10 mM ETH 500 in dichloroethane. The electrodes were characterized by determining the st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 86  شماره 

صفحات  -

تاریخ انتشار 2014