Reduction of nonspecific protein adsorption on cantilever biosensors caused by transverse resonant mode vibration.

نویسندگان

  • Blake N Johnson
  • Raj Mutharasan
چکیده

We examine if vibration of millimeter-sized cantilever sensors can release nonspecifically adsorbed proteins. Integrated electrochemical and mass-change measurement as well as fluorescence assays showed transverse surface vibration released nonspecifically bound proteins in samples prepared at 0.2-3.6 mg bovine serum albumin (BSA) per mL. Extent of release was directly related to magnitude of excitation voltage (Vex) applied to the self-actuating lead zirconate titanate (PZT) cantilever over three log units (0, 10 mV, 100 mV, and 1 V). Vibration-induced release was not instantaneous, but had an apparent first-order rate constant (kapp) which ranged from 0.02-0.1 min(-1). Results suggest significant serum albumin protein release could be achieved using excitation voltages of 1 V in millimeter-sized cantilever sensors. Complementary experiments with thiolated DNA, which binds to surface gold 〈111〉 sites with ∼ four times higher binding energy than BSA, showed negligible release under the same vibration magnitude. The results of the study suggest a direct correlation between surface-adsorbate binding energy and the effectiveness of vibration-induced release. We suggest that the release mechanism includes contributions from surface strain energy, body force, and acoustic streaming-associated hydrodynamic effects. The primary contribution of this study suggests that surface vibration of cantilever sensors may be useful in reducing nonspecific adsorption, especially for biosensing of analytes present in a complex background.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of bacteria based on the thermomechanical noise of a nanomechanical resonator: origin of the response and detection limits.

We have measured the effect of bacteria adsorption on the resonant frequency of microcantilevers as a function of the adsorption position and vibration mode. The resonant frequencies were measured from the Brownian fluctuations of the cantilever tip. We found that the sign and amount of the resonant frequency change is determined by the position and extent of the adsorption on the cantilever wi...

متن کامل

An Investigation into Resonant Frequency of Triangular V-Shaped Cantilever Piezoelectric Vibration Energy Harvester

Power supply is a bottle-neck problem of wireless micro-sensors, especially where the replacement of batteries is impossible or inconvenient. Now piezoelectric material is being used to harvest vibration energy for self-powered sensors. However, the geometry of a piezoelectric cantilever beam will greatly affect its vibration energy harvesting ability. This paper deduces a remarkably precise an...

متن کامل

Sensitivity of a Label-Free Guided-Mode Resonant Optical Biosensor with Different Modes

Sensitivity is a key factor in the performance of a sensor. To achieve maximum guided-mode resonant optical biosensor sensitivity, a comparison of biosensor sensitivity for Transverse Electric (TE) and Transverse Magnetic (TM) modes based on the distribution of electric fields is presented in this article. A label-free guided-mode resonant optical biosensor is designed using the quarter-wave an...

متن کامل

Resonant frequency of bimorph triangular V-shaped piezoelectric cantilever energy harvester

The concept of “energy harvesting” is to design smart systems to capture the ambient energy and to convert it to usable electrical power for supplying small electronics devices and sensors. The goal is to develop autonomous and self-powered devices that do not need any replacement of traditional electrochemical batteries. Now piezoelectric cantilever structures are being used to harvest vibrati...

متن کامل

Study of the flexural sensitivity and resonant frequency of an inclined AFM cantilever with sidewall probe

The resonant frequency and sensitivity of an atomic force microscope (AFM) cantilever with assembled cantilever probe (ACP) have been analyzed and a closed-form expression for the sensitivity of vibration modes has been obtained. The proposed ACP comprises an inclined cantilever and extension, and a tip located at the free end of the extension, which makes the AFM capable of topography at sidew...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 139 5  شماره 

صفحات  -

تاریخ انتشار 2014