Efficiency of a grazing-incidence off-plane grating in the soft-x-ray region.
نویسندگان
چکیده
Efficiency measurements of a grazing-incidence diffraction grating in the off-plane mount were performed using polarized synchrotron radiation. The grating had 5000 grooves/mm, an effective blaze angle of 14 degrees, and was gold coated. The efficiencies in the two polarization orientations (TM and TE) were measured in the 1.5-5.0 nm wavelength range and were compared with the efficiencies calculated using the PCGrate-SX code. The TM and TE efficiencies differ, offering the possibility of performing unique science studies of astrophysical, solar, and laboratory sources by exploiting the polarization sensitivity of the off-plane grating.
منابع مشابه
Off-plane grating mount tolerances for Constellation-X
High groove density reflection gratings placed at grazing incidence in the extreme off-plane mount offer increased performance over conventional in-plane mounts in the x-ray. We are developing an off-plane approach to the Reflection Grating Spectrometer of the Constellation-X Mission. In this paper we discuss the geometry of the off-plane mount and present formulae for the key tolerances of the...
متن کاملFabrication and performance of blazed transmission gratings for x-ray astronomy
We have developed a new type of soft x-ray diffraction grating. This critical-angle transmission (CAT) grating combines the advantages of traditional transmission gratings (low mass, extremely relaxed alignment and flatness tolerances) with those of x-ray reflection gratings (high efficiency due to blazing in the direction of grazing-incidence reflection, increased resolution due to the use of ...
متن کاملInterference Methods In The Testing And Fabrication Of New- Design Grazing Incidence Gratings
Recent work in the design of soft X -ray and extreme UV spectrographs has identified a new class of reflection gratings whose aberrations do not increase at grazing incidence. To achieve this characteristic, the groove spacings are varied in a continuous manner across a plano grating aperture. Ray traces of the concentric groove grating, the oriental fan grating and variations illustrate their ...
متن کاملExperimental setup for high resolution X-ray spectroscopy of solids and liquid samples
Here we present a next-generation experimental setup for high-resolution X-ray spectroscopy of solid and liquid samples in the soft X-ray region to elucidate the complex molecular structures of (bio)chemical systems. The setup consists of a main target chamber, a target holder for either solid samples or a liquid jet delivery system, and a high-resolution soft Xray grating spectrometer. This se...
متن کاملDevelopment of a critical-angle transmission grating spectrometer for the International X-Ray Observatory
We present a high-resolution soft x-ray grating spectrometer concept for the International X-Ray Observatory (IXO) that meets or exceeds the minimum requirements for effective area (> 1, 000 cm for E < 1 keV) and spectral resolution (E/ΔE > 3, 000). At the heart of the spectrometer is an array of recently developed highefficiency blazed transmission gratings, the so-called critical-angle transm...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Applied optics
دوره 45 8 شماره
صفحات -
تاریخ انتشار 2006