Evaluation of Power Factor Corrected AC - DC Converters and Controllers to meet UPS Performance Index
نویسندگان
چکیده
Harmonic pollution and low power factor in power systems caused by power converters have been of great concern. To overcome these problems several converter topologies using advanced semiconductor devices and control schemes have been proposed. This investigation is to identify a low cost, small size, efficient and reliable ac to dc converter to meet the input performance index of UPS. The performance of single phase and three phase ac to dc converter along with various control techniques are studied and compared. The half bridge converter topology with linear current control is identified as most suitable. It is simple, energy efficient because of single switch power loss and transformer-less operation of UPS. The results are validated practically using a prototype built using IGBT and analog controller. The performance for both single and three-phase system is verified. Digital implementation of closed loop control achieves higher reliability. Its cost largely depends on chosen bit precision. The minimal bit precision for optimum converter performance is identified as 16-bit with fixed-point operation. From the investigation and practical implementation it is concluded that half bridge ac – dc converter along with digital linear controller meets the performance index of UPS for single and three phase systems. Keywords—PFC, energy efficient, half bridge, ac-dc converter, boost topology, linear current control, digital bit precision.
منابع مشابه
Boost Converter for Power Factor Correction of DC Motor Drive
With the increasing demand for power from the ac line and more stringent limits for power quality, power factor correction has gained great attention in recent years. A variety of circuit topologies and control methods have been developed for the PFC application. While the discontinuous conduction mode (DCM) converters such as boost and flyback converters are well suited for low power applicati...
متن کاملModified Bi-directional AC/DC Power Converter with Power Factor Correction
Most existing power converters and industrial motor drive systems draw non-sinusoidal currents from the supply. Non-sinusoidal currents contained harm harmonics disturb the power supply which it causes serious concern for reliability. Other equipments that use the same power supply are adversely affected. This paper suggests the operation and performance of a new modified AC/DC converter that ...
متن کاملAC/DC Converter with Active Power Factor Correction Applied to DC Motor Drive
–Harmonic pollution and low power factor in power systems caused by power converters have been of great concern. To overcome these problems several converter topologies using advanced semiconductor devices and control schemes have been proposed. This investigation is to identify a low cost, small size, efficient and reliable ac to dc converter to meet the input performance index of UPS. The per...
متن کاملPower Factor Correction Using Step-Up Chopper Fed to a DC Motor Drive
With the expanding interest for power from the ac line and more stringent cutoff points for power quality, power factor correction is extraordinary consideration as of late. An assortment of circuit topologies and control strategies has been created for the PFC application. While the discontinuous conduction mode (DCM) converters for example, boost and fly back converters are appropriate for lo...
متن کاملمبدل AC-DC24 پالسه مبتنی بر اتوترانسفورماتورچنگالی به منظور بهبود شاخصهای کیفیت توان
In this paper, a 24-pulse ac-dc converter is designed, modeled and simulated based on a fork autotransformer to improve power quality indices. The use of autotransformer results in reduced kVA rating of the proposed topology as compared with the transformer based 24-pulse converter. Due to the proper flexibility of the proposed topology, it can be simply utilized in other similar applications. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009