How does knowledge of three-dimensional excision margins following breast conservation surgery impact upon clinical target volume definition for partial-breast radiotherapy?

نویسندگان

  • Anna M Kirby
  • Philip M Evans
  • Ashutosh Y Nerurkar
  • Saral S Desai
  • Jaroslaw Krupa
  • Haresh Devalia
  • Guidubaldo Querci della Rovere
  • Emma J Harris
  • Julia Kyriakidou
  • John R Yarnold
چکیده

BACKGROUND AND PURPOSE To compare partial-breast clinical target volumes generated using a standard 15 mm margin (CTV(standard)) with those generated using three-dimensional surgical excision margins (CTV(tailored 30)) in women who have undergone wide local excision (WLE) for breast cancer. MATERIAL AND METHODS Thirty-five women underwent WLE with placement of clips in the anterior, deep and coronal excision cavity walls. Distances from tumour to each of six margins were measured microscopically. Tumour bed was defined on kV-CT images using clips. CTV(standard) was generated by adding a uniform three-dimensional 15 mm margin, and CTV(tailored 30) was generated by adding 30 mm minus the excision margin in three-dimensions. Concordance between CTV(standard) and CTV(tailored 30) was quantified using conformity (CoI), geographical-miss (GMI) and normal-tissue (NTI) indices. An external-beam partial-breast irradiation (PBI) plan was generated to cover 95% of CTV(standard) with the 95% isodose. Percentage-volume coverage of CTV(tailored 30) by the 95% isodose was measured. RESULTS Median (range) coronal, superficial and deep excision margins were 15.0 (0.5-76.0)mm, 4.0 (0.0-60.0)mm and 4.0 (0.5-35.0)mm, respectively. Median CoI, GMI and NTI were 0.62, 0.16 and 0.20, respectively. Median coverage of CTV(tailored 30) by the PBI-plan was 97.7% (range 84.9-100.0%). CTV(tailored 30) was inadequately covered by the 95% isodose in 4/29 cases. In three cases, the excision margin in the direction of inadequate coverage was <or=2mm. CONCLUSIONS CTVs based on 3D excision margin data are discordant with those defined using a standard uniform 15 mm TB-CTV margin. In women with narrow excision margins, the standard TB-CTV margin could result in a geographical miss. Therefore, wider TB-CTV margins should be considered where re-excision does not occur.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric Comparison of 3D Tangential Radiotherapy of Post-Lumpectomy Breast at Two Different Energies

Introduction: Radiation therapy following breast conserving surgery is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is almost always the technique of choice for this purpose. This technique is often performed based on 3D treatment planning. The aim of this study was to compare 3D treatment planning for two different energie...

متن کامل

Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy.

BACKGROUND Accelerated partial breast irradiation (APBI) is a new breast treatment modality aiming to reduce treatment time using hypo fractionation. Compared to conventional whole breast irradiation that takes 5 to 6 weeks, APBI is reported to induce worse cosmetic outcomes both when using three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT). These late...

متن کامل

High resolution intra-operative two-dimensional specimen mammography and its impact on second operation for re-excision of positive margins at final pathology after breast conservation surgery.

BACKGROUND In the United States, about 50% to 66% of women undergoing breast conservation surgery for cancer undergo subsequent mastectomy for positive margins on initial lumpectomy. This is despite the fact that screening mammography has resulted in a decrease in the size of newly diagnosed breast cancer to <2 cm. METHODS A retrospective review of 128 patients who underwent breast conservati...

متن کامل

Axillary irradiation in breast cancer; does meticulous contouring make a difference?

Background: Due to the current trends towards replacing axillary dissection with radiotherapy, the need for more precise definition for different nodal stations becomes a must to ensure safe and adequate dose coverage. So, our study aimed to evaluate the coverage of axillary nodal volumes based on Project on Cancer of the Breast (PROCAB) guidelines, for cases previously treated with our standar...

متن کامل

How does imaging frequency and soft tissue motion affect the PTV margin size in partial breast and boost radiotherapy?

PURPOSE This study investigates (i) the effect of verification protocols on treatment accuracy and PTV margins for partial breast and boost breast radiotherapy with short fractionation schema (15 fractions), (ii) the effect of deformation of the excision cavity (EC) on PTV margin size, (iii) the imaging dose required to achieve specific PTV margins. METHODS AND MATERIALS Verification images u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology

دوره 94 3  شماره 

صفحات  -

تاریخ انتشار 2010