Analytical Interference in Serum Iron Determination Reveals Iron Versus Gadolinium Transmetallation With Linear Gadolinium-Based Contrast Agents

نویسندگان

  • Nathalie Fretellier
  • Nathalie Poteau
  • Cécile Factor
  • Jean-François Mayer
  • Christelle Medina
  • Marc Port
  • Jean-Marc Idée
  • Claire Corot
چکیده

OBJECTIVES The purposes of this study were to evaluate the risk for analytical interference with gadolinium-based contrast agents (GBCAs) for the colorimetric measurement of serum iron (Fe³⁺) and to investigate the mechanisms involved. MATERIALS AND METHODS Rat serum was spiked with several concentrations of all molecular categories of GBCAs, ligands, or "free" soluble gadolinium (Gd³⁺). Serum iron concentration was determined by 2 different colorimetric methods at pH 4.0 (with a Vitros DT60 analyzer or a Cobas Integra 400 analyzer). Secondly, the cause of interference was investigated by (a) adding free soluble Gd³⁺ or Mn²⁺ to serum in the presence of gadobenic acid or gadodiamide and (b) electrospray ionization mass spectrometry. RESULTS Spurious decrease in serum Fe³⁺ concentration was observed with all linear GBCAs (only with the Vitros DT60 technique occurring at pH 4.0) but not with macrocyclic GBCAs or with free soluble Gd³⁺. Spurious hyposideremia was also observed with the free ligands present in the pharmaceutical solutions of the linear GBCAs gadopentetic acid and gadodiamide (ie, diethylene triamine pentaacetic acid and calcium-diethylene triamine pentaacetic acid bismethylamide, respectively), suggesting the formation of Fe-ligand chelate.Gadobenic acid-induced interference was blocked in a concentration-dependent fashion by adding a free soluble Gd³⁺ salt. Conversely, Mn²⁺, which has a lower affinity than Gd³⁺ and Fe³⁺ for the ligand of gadobenic acid (ie, benzyloxypropionic diethylenetriamine tetraacetic acid), was less effective (interference was only partially blocked), suggesting an Fe³⁺ versus Gd³⁺ transmetallation phenomenon at pH 4.0. Similar results were observed with gadodiamide. Mass spectrometry detected the formation of Fe-ligand with all linear GBCAs tested in the presence of Fe and the disappearance of Fe-ligand after the addition of free soluble Gd³⁺. No Fe-ligand chelate was found in the case of the macrocyclic GBCA gadoteric acid. CONCLUSIONS Macrocyclic GBCAs induced no interference with colorimetric methods for iron determination, whereas negative interference was observed with linear GBCAs using a Vitros DT60 analyzer. This interference of linear GBCAs seems to be caused by the excess of ligand and/or an Fe³⁺ versus Gd³⁺ transmetallation phenomenon.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Systematic review: Superparamagnetic Iron Oxide nanoparticles as contrast agents in diagnosis of multiple sclerosis

Several MRI contrast agents (CAs) are used in medical diagnosis that gadolinium (Gd3+) is the most widely used as contrast agents. Unfortunately, its toxicity is due to its inefficiency. In this review, we discuss about the ability of SPIONs in MRI and application in Multiple Sclerosis diagnosis. Superparamagnetic iron oxide nanoparticles (SPIONs) such as magnetite nanoparticles are used as goo...

متن کامل

Systematic review: Superparamagnetic Iron Oxide nanoparticles as contrast agents in diagnosis of multiple sclerosis

Several MRI contrast agents (CAs) are used in medical diagnosis that gadolinium (Gd3+) is the most widely used as contrast agents. Unfortunately, its toxicity is due to its inefficiency. In this review, we discuss about the ability of SPIONs in MRI and application in Multiple Sclerosis diagnosis. Superparamagnetic iron oxide nanoparticles (SPIONs) such as magnetite nanoparticles are used as goo...

متن کامل

Interference of medical contrast media on laboratory testing

The use of contrast media such as organic iodine molecules and gadolinium contrast agents is commonplace in diagnostic imaging. Although there is widespread perception that side effects and drug interactions may be the leading problems caused by these compounds, various degrees of interference with some laboratory tests have been clearly demonstrated. Overall, the described interference for iod...

متن کامل

Analytical Interference by Contrast Agents in Biochemical Assays

Objective To provide a clinically relevant overview of the analytical interference by contrast agents (CA) in laboratory blood test measurements. Materials and Methods The effects of five CAs, gadobutrol, gadoterate meglumine, gadoxetate disodium, iodixanol, and iomeprol, were studied on the 29 most frequently performed biochemical assays. One-day-old plasma, serum, and whole blood were spike...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 49  شماره 

صفحات  -

تاریخ انتشار 2014