Accuracy and impact of Xpert MTB/RIF for the diagnosis of smear-negative or sputum-scarce tuberculosis using bronchoalveolar lavage fluid.

نویسندگان

  • Grant Theron
  • Jonny Peter
  • Richard Meldau
  • Hoosain Khalfey
  • Phindile Gina
  • Brian Matinyena
  • Laura Lenders
  • Gregory Calligaro
  • Brian Allwood
  • Gregory Symons
  • Ureshnie Govender
  • Mashiko Setshedi
  • Keertan Dheda
چکیده

RATIONALE The accuracy and impact of new tuberculosis (TB) tests, such as Xpert MTB/RIF, when performed on bronchoalveolar lavage fluid (BALF) obtained from patients with sputum-scarce or smear-negative TB is unclear. METHODS South African patients with suspected pulmonary TB (n=160) who were sputum-scarce or smear-negative underwent bronchoscopy. MTB/RIF was performed on uncentrifuged BALF (1 ml) and/or a resuspended pellet of centrifuged BALF (∼10 ml). Time to TB detection and anti-TB treatment initiation were compared between phase one, when MTB/RIF was performed as a research tool, and phase two, when it was used for patient management. RESULTS 27 of 154 patients with complete data had culture-confirmed TB. Of these, a significantly lower proportion were detected by smear microscopy compared with MTB/RIF (58%, 95% CI 39% to 75% versus 93%, 77% to 98%; p<0.001). Of the 127 patients who were culture negative, 96% (91% to 98%) were MTB/RIF negative. When phase two was compared with phase one, MTB/RIF reduced the median days to TB detection (29 (18-41) to 0 (0-0); p<0.001). However, more patients initiated empirical therapy (absence of a positive test in those commencing treatment) in phase one versus phase two (79% (11/14) versus 28% (10/25); p=0.026). Consequently, there was no detectable difference in the overall proportion of patients initiating treatment (26% (17/67; 17% to 37%) versus 36% (26/73; 26% to 47%); p=0.196) or the days to treatment initiation (10 (1-49) versus 7 (0-21); p=0.330). BALF centrifugation, HIV coinfection and a second MTB/RIF did not result in detectable changes in accuracy. CONCLUSIONS MTB/RIF detected TB cases more accurately and more rapidly than smear microscopy and significantly reduced the rate of empirical treatment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic yield of Bronchoalveolar Lavage gene Xpert in smear-negative and sputum-scarce pulmonary tuberculosis.

OBJECTIVE To measure the diagnostic yield of Bronchoalveolar Lavage (BAL) gene Xpert (Xpert MTB/RIF assay), to detect Mycobacterium tuberculosis (MTB) and rifampicin resistance and compare it with that of mycobacterial cultures in a suspected case of pulmonary tuberculosis. STUDY DESIGN An analytical study. PLACE AND DURATION OF STUDY Department of Pulmonology, Fauji Foundation Hospital (FF...

متن کامل

Rapid Diagnosis of Childhood Pulmonary Tuberculosis by Xpert MTB/RIF Assay Using Bronchoalveolar Lavage Fluid

In order to evaluate the diagnostic accuracy of the Xpert MTB/RIF assay on childhood pulmonary tuberculosis (PTB) using bronchoalveolar lavage fluid (BALF), we evaluated the sensitivity, specificity, positive predictive value, and negative predictive value of Xpert MTB/RIF assay using BALF in comparison with acid-fast bacilli (AFB) microscopy and Mycobacterium tuberculosis (MTB) culture for dia...

متن کامل

A Comprehensive Evaluation of Xpert MTB/RIF Assay With Bronchoalveolar Lavage Fluid as a Single Test or Combined With Conventional Assays for Diagnosis of Pulmonary Tuberculosis in China: A Two-Center Prospective Study

Introduction: The Xpert MTB/RIF is recommended by the World Health Organization as a first line rapid test for the diagnosis of pulmonary tuberculosis (TB); however, China does not routinely use this test, partially due to the lack of a sufficient number of systematic evaluations of this assay in local patients. The aims of this study were to comprehensively assess the diagnostic performance of...

متن کامل

Retrospective observational study of diagnostic accuracy of the Xpert® MTB/RIF assay on fiberoptic bronchoscopy sampling for early diagnosis of smear-negative or sputum-scarce patients with suspected tuberculosis

BACKGROUND Fiberoptic bronchoscopy (FOB) is a useful diagnosis tool in low-burden countries for patients with suspected pulmonary tuberculosis (TB) who are smear-negative or sputum-scarce. This study sought to determine the accuracy of the Xpert® MTB/RIF (XP) assay using FOB samples. METHODS We retrospectively reviewed clinical, radiological, and microbiological characteristics of 175 TB-susp...

متن کامل

The Value of Bronchoalveolar Lavage in the Diagnosis of Sputum Smear-NegativePulmonary Tuberculosis

Background and Objectives: Sputum smear staining for acid-fast bacilli is initial approach to the diagnosis of pulmonary tuberculosis (PTB) but more than 50% of cases are sputum smear-negative. This study was aimed to investigate the diagnostic value of fiberoptic bronchoscopy (FOB) guided bronchoalveolar lavage (BAL) in patients suspected to have tuberculosis. Methods: This prospective cross-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Thorax

دوره 68 11  شماره 

صفحات  -

تاریخ انتشار 2013