LESS sacrocolpopexy: step by step of a simplified knotless technique.

نویسندگان

  • Marcos Tobias-Machado
  • Felipe A Chicoli
  • Renato M M Costa
  • Alexandre Stievano Carlos
  • Carlos A Bezerra
  • Luiz F F Longuino
  • Eduardo S Starling
  • André L F Tome
  • Antonio C L Pompeo
چکیده

INTRODUCTION Pelvic organ prolapse is an ordinary disease with around 200.000 surgeries performed annually in the US to treat this condition. The surgical treatment for complete vaginal vault prolapse after hysterectomy involves abdominal or vaginal sacrocolpopexy. The purpose of this video is to demonstrate the steps of a laparoendoscopic single-site surgery (LESS) sacrocolpopexy performed by a simplified knotless technique. MATERIALS AND METHODS A 52 year-old female submitted a total hysterectomy five years ago due to miomatosis who developed vault prolapse and urinary incontinence after surgery. She was treated by transumbilical LESS cutaneous retractor and a surgical glove attached to three trocars through a 3.5 cm umbilical incision. Patient was positioned in lithotomy, the Y-shape polypropylene mesh was passed through the trocar. Only conventional laparoscopic instruments were used for intrabdominal dissection of vagina and peritoneum. The mesh was fixed to the vaginal fornix using 3 continuous sutures held in extremities by polymeric clips. The last helical suture was fixed by polymeric clips to the sacral periosteum from the promontory to achieve good vaginal positioning without tension. The posterior peritoneum was closed over the mesh. RESULTS The operative time was 150 minutes, blood loss of approximately 100 mL and the patient was discharged after 18 hours with no immediate complications and a 3 months follow-up free of vault prolapse and urinary incontinence until now. CONCLUSIONS LESS sacrocolpopexy performed with conventional instruments is feasible and a safe procedure reproducing surgical steps of conventional laparoscopic or robotic surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Arthroscopic Double-Row Transosseous Equivalent Rotator Cuff Repair with a Knotless Self-Reinforcing Technique

BACKGROUND Rotator cuff tears are a significant cause of shoulder morbidity. Surgical techniques for repair have evolved to optimize the biologic and mechanical variables critical to tendon healing. Double-row repairs have demonstrated superior biomechanical advantages to a single-row. METHODS The preferred technique for rotator cuff repair of the senior author was reviewed and described in a...

متن کامل

A Simplified and Reproducible Two-Step Method for the Purification of Prostate-Specific Antigen

Prostate-specific antigen (PSA) was purified to homogeneity from human seminal plasma by ion-exchange chromatography on a CM-Sephadex C-50 and by gel filtration on a Sephacryl S-200 column. A single 33-kDa protein band appeared in SDS-PAGE. High pressure liquid chromatography (HPLC) of the purified protein produced a single peak, while isoelectric focusing demonstrated the presence of five diff...

متن کامل

A Two-step Method for the Preparation of Implant Recipient Site in Severe Atrophic Maxilla: A Case Report of the Alveolar Ridge Split Technique Followed by Bone Expansion

Augmentation of deficient and atrophic alveolar ridges is an important aspect of dental implant therapy with the goal of providing a functional restoration in harmony with adjacent natural dentition. Bone splitting technique is considered a distinguished augmentation method for treatment of deficient alveolar ridges. According to this procedure, the compromised alveolar ridge is opened from the...

متن کامل

Dimensional accuracy of three impression materials by one-step and two-step impression techniques: An in vitro study

Introduction: An accurate impression is essential to create a well-fitted dental prosthesis. This study aimed to compare the dimensional accuracy of three elastomeric materials using one-step and two-step impression techniques. Methods: In this study, 20 impressions were fabricated for each Vinyl siloxane ether (Identium), condensation silicone (Speedex), and a...

متن کامل

Feasibility and Safety of Absorbable Knotless Wound Closure Device in Laparoscopic Myomectomy

Purpose. Myomectomy has been performed through laparoscopy. Suturing is known as rate-limiting step in laparoscopic myomectomy. The present study was aimed at comparing the clinical outcomes of absorbable knotless wound closure device with the results of conventional suturing. Methods. This prospective study included 62 women who underwent laparoscopic myomectomy at Taipei City Hospital, Zhongx...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International braz j urol : official journal of the Brazilian Society of Urology

دوره 38 6  شماره 

صفحات  -

تاریخ انتشار 2012