Accuracy of Component Orientation and Leg Length Adjustment in Total Hip Arthroplasty Using Image-free Navigation
نویسندگان
چکیده
Purpose The purpose of this study was to examine the accuracy of implant orientation and leg length in total hip arthroplasty (THA) with an image-free navigation system based on a comparison of the intraoperative navigation and postoperative CT evaluations. Material and Methods A consecutive series of 111 patients (118 hips) who underwent THA using the current version of the image-free navigation system constituted the basic study population. Subsequently, a total of 101 patients (108 hips) meeting the inclusion and exclusion criteria were selected as study subjects for the analysis. THA was performed using an image-free navigation system that was capable of adjusting both the prosthetic position and leg length. Postoperative CT examination was performed for all study subjects, and the prosthetic position and leg length were measured on CT images using the image analysis software. Subsequently, the intraoperative navigation results and the corresponding values obtained from the postoperative CT measurements were compared to test the accuracy of the navigation system. Results The average discrepancies between the intra- and postoperative assessments were 6.8°, 3.7°, and 5.7° for cup anteversion, cup inclination, and stem anteversion, respectively. The corresponding value in leg length averaged 4.1 mm. Conclusion Average discrepancies between the intra- and postoperative measurements were less than 10° in all prosthetic alignment parameters and less than 5 mm in leg length. Intraoperative assessments with the use of the image-free navigation in THA could afford satisfactory result.
منابع مشابه
Accuracy of Component Orietation and Leg Length Adjustments Using a Revised Version Image-free Navigation in Total Hip Arthroplasty
We have been using an imageless navigation in total hip arthroplasty (THA) since 2006. In our previous studies, we reported that the use of the initial version image-free navigation system (Orthopilot ver1.1, and Orthopilot THAplus B/BRAUN-Aesculap, Germany) could achieve satisfactory accuracy and consistency in cup positioning. However, the system of this version did not include the software t...
متن کاملIntellijoint HIP®: a 3D mini-optical navigation tool for improving intraoperative accuracy during total hip arthroplasty
Total hip arthroplasty is an increasingly common procedure used to address degenerative changes in the hip joint due to osteoarthritis. Although generally associated with good results, among the challenges associated with hip arthroplasty are accurate measurement of biomechanical parameters such as leg length, offset, and cup position, discrepancies of which can lead to significant long-term co...
متن کاملA new mini-navigation tool allows accurate component placement during anterior total hip arthroplasty
Introduction Computer-assisted navigation systems have been explored in total hip arthroplasty (THA) to improve component positioning. While these systems traditionally rely on anterior pelvic plane registration, variances in soft tissue thickness overlying anatomical landmarks can lead to registration error, and the supine coronal plane has instead been proposed. The purpose of this study was ...
متن کاملClinical Study for Measurement of Stem Antetorsion during Total Hip Arthroplasty. Ct Free Navigation Vs G-guide
Implant positioning is one of the critical factors influencing the postoperative outcome in total hip arthroplasty (THA) [1.2]. In our previous study, we evaluated the Combined anteversion (CA) value in patients who underwent THA using an image-free navigation for the cup with manual adjustment of the stem. Consequently, the AT value showed wide variability [3].Since March 2013, we have measure...
متن کاملComputed tomography-based surgical navigation for hip arthroplasty.
Component malpositioning and postoperative leg length discrepancy are the most common technical problems associated with total hip arthroplasty (THA). Surgical navigation offers the potential to reduce the incidence of these problems. We reviewed 317 patients (344 hips) that underwent THA using computed tomography-based surgical navigation, including 112 THAs using a simplified method of measur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 11 شماره
صفحات -
تاریخ انتشار 2017