Two-channel snapshot Mueller matrix polarimeter.
نویسندگان
چکیده
We describe a new setup for a snapshot Mueller matrix polarimeter (SMMP). It relies on the separation and orthogonal polarization of two light beams by a Wollaston prism located at the setup output. The simultaneous treatment of the two spectra allows an enhancement of accuracy for real-time measurements through reduction of the effects caused by random noise and systematic errors. Moreover, it gives insight into the nonuniform spectral response of the medium under study. Experimental results support the feasibility of the proposed technique.
منابع مشابه
Snapshot retinal imaging Mueller matrix polarimeter
Early diagnosis of glaucoma, which is a leading cause for visual impairment, is critical for successful treatment. It has been shown that Imaging polarimetry has advantages in early detection of structural changes in the retina. Here, we theoretically and experimentally present a snapshot Mueller Matrix Polarimeter fundus camera, which has the potential to record the polarization-altering chara...
متن کاملSystematic errors specific to a snapshot Mueller matrix polarimeter.
Systematic errors specific to a snapshot Mueller matrix polarimeter are studied. Their origins and effects are highlighted, and solutions for correction and stabilization are proposed. The different effects induced by them are evidenced by experimental results acquired with a given setup and theoretical simulations carried out for more general cases. We distinguish the errors linked to some imp...
متن کاملSnapshot imaging Mueller matrix polarimeter using polarization gratings.
A snapshot imaging Mueller matrix polarimeter (SIMMP) is theoretically described and empirically demonstrated through simulation. Spatial polarization fringes are localized onto a sample by incorporating polarization gratings (PGs) into a polarization generator module. These fringes modulate the Mueller matrix (MM) components of the sample, which are subsequently isolated with PGs in an analyze...
متن کاملTime-resolved switching analysis of a ferroelectric liquid crystal by snapshot Mueller matrix polarimetry.
An experimental snapshot Mueller matrix polarimeter based on wavelength polarization coding is used to get a time-resolved description of electric-field-induced fast transition within a ferroelectric liquid-crystal cell. The parameters extracted from experimental Mueller matrices are linked to the molecule director distribution to further determine the average trajectory and the collective beha...
متن کاملSnapshot Mueller matrix polarimeter by wavelength polarization coding.
We present a new, to the best of our knowledge, experimental configuration of Mueller matrix polarimeter based on wavelength polarization coding. This is a compact and fast technique to study polarization phenomena. Our theoretical approach, the necessity to correct systematic errors and our experimental results are presented. The feasibility of the technique is tested on vacuum and on a linear...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Applied optics
دوره 48 33 شماره
صفحات -
تاریخ انتشار 2009