Bipolar and multipolar radio frequency ablation with resistance controlled power output: standardized ex vivo kidney tissue evaluation.

نویسندگان

  • Axel Häcker
  • Stefan Vallo
  • Christel Weiss
  • Rainer Grobholz
  • Thomas Stein
  • Thomas Knoll
  • Maurice Stephan Michel
چکیده

PURPOSE We investigated a newly developed bipolar and multipolar RF ablation system with an internally cooled electrode and resistance controlled power output in a standardized model of perfused ex vivo kidney tissue. MATERIALS AND METHODS RF energy was applied at different power levels (20, 30 and 60 W) for 1, 3, 5 and 9 minutes. Each treatment parameter was repeated 5 times. For the 20/30 W levels a bipolar electrode with an active conducting part of 20/30 mm was selected. At 60 W 2 bipolar electrodes with an active conducting part (30 mm each) were connected. Lesion volumes and shapes were calculated by measuring the maximum vertical, long axis and short axis diameters of the macroscopic lesion. RESULTS Lesion volume increased significantly with the treatment time and generator power applied (p < 0.0001). Lesion size in multipolar ablated zones was larger than that in bipolar ablated zones. A reliable dose-effect relationship existed between the generator power/applied treatment time and ablated tissue lesion size. All lesions were elliptical. CONCLUSIONS Bipolar and multipolar RF ablation with an internally cooled electrode and tissue resistance control represent an interesting advance in RF technology. The development of lesion size and volume is predictable, while a uniform lesion shape can be achieved in perfused ex vivo kidney tissue. Further in vivo trials are required to test whether complete and reliable tumor tissue ablation is possible with this system.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multipolar radiofrequency ablation with internally cooled electrodes: experimental study in ex vivo bovine liver with mathematic modeling.

PURPOSE To evaluate the size and geometry of thermally induced coagulation by using multipolar radiofrequency (RF) ablation and to determine a mathematic model to predict coagulation volume. MATERIALS AND METHODS Multipolar RF ablations (n = 80) were performed in ex vivo bovine livers by using three internally cooled bipolar applicators with two electrodes on the same shaft. Applicators were ...

متن کامل

Bipolar radiofrequency ablation of the kidney: comparison with monopolar radiofrequency ablation.

PURPOSE We report initial ex vivo and in vivo studies using bipolar radiofrequency (RF) ablation of porcine kidneys. An internal ground electrode is positioned in the kidney opposite the RF electrode, resulting in ablation of all the intervening renal tissue. MATERIALS AND METHODS Ex vivo preparations of 10 porcine kidneys were perfused continuously with Ringer's solution and treated with eit...

متن کامل

Ex vivo evaluation of a bipolar application concept for radiofrequency ablation.

BACKGROUND Bipolar radiofrequency ablation (RFA) can avoid complications such as thermal tissue damage, a possible consequence of monopolar RFA. However, basic studies about the dosage/effect relationship of bipolar systems are missing. This is systematic research on ex vivo beef livers to find which capacity parameters produce high energy in the tissue and achieve large lesion volumes. MATER...

متن کامل

Software Tool for the Analysis of the Coagulation Zone from Multipolar Radiofrequency Ablation

Percutaneous radiofrequency (RF) ablation is becoming a standard minimal invasive procedure for treatment of primary liver tumors. In clinical practice, knowledge about geometry and expected size of the coagulation is essential to prevent local tumor recurrence. Particularly the heat-sink effects of large vessels in the vicinity of the electrode may lead to a smaller size of the coagulation zon...

متن کامل

The Vista system: a new bipolar resection device for endourological procedures: comparison with conventional resectoscope.

OBJECTIVE Conventional transurethral resection of the prostate (TURP) uses a monopolar electrocautery system in which the current passes from the active electrode through the patient's body towards the return plate and may cause distant negative effects. In this study a new developed resection device, the Vista system, using a bipolar electrocautery system and 0.9% sodium chloride solution for ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of urology

دوره 175 3 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2006