Intracardiac ultrasound measurement of volumes and ejection fraction in normal, infarcted, and aneurysmal left ventricles using a 10-MHz ultrasound catheter.

نویسندگان

  • C Chen
  • J L Guerrero
  • J A Vazquez de Prada
  • L R Padial
  • E Schwammenthal
  • M H Chen
  • L Jiang
  • T Svizzero
  • H Simon
  • J D Thomas
چکیده

BACKGROUND Our objective was to examine the accuracy of intracardiac ultrasound (ICUS) measurement of left ventricular (LV) volumes and ejection fraction (EF) using a 10-MHz ultrasound catheter. ICUS can image the LV in cross sections at all levels along the long axis with a transducer mounted on the tip of a catheter. Sequential serial LV cross-sectional images can be obtained during cardiac catheterization and used to calculate LV volumes by Simpson's rule. This technique may be an alternative to contrast LV angiography. METHODS AND RESULTS A beating-heart in vivo model was created to measure LV volume directly and continuously with an intracavity high-compliance latex balloon connected to a calibrated extracardiac reservoir in eight dogs in 35 experimental stages. A 10F ICUS catheter with a 10-MHz single-element transducer was introduced retrogradely via the aortic valve to the apex. Series of sequential LV cross-sectional images were recorded from the apex to the base during a calibrated pullback of the catheter. At each 5-mm interval, the LV cross section was traced at end diastole and end systole. LV volume was calculated by Simpson's rule by integrating all segmental areas multiplied by segmental height. The effect on accuracy of selecting 5-, 10-, or 15-mm heights or a single section at the midventricular level for measurement was assessed. The influence of distorted ventricular shape on the accuracy of ICUS measurements of LV volume was evaluated. This method was applied in 19 experimental stages in 10 intact dogs and pigs catheterized via the femoral artery. In the in vivo canine model, LV end-diastolic volume, end-systolic volume, and EF determined by ICUS using 5-, 10-, or 15-mm segments were not different from the actual measurements. But correlation and agreement between ICUS end-diastolic volume and direct measurements for 5- and 10-mm segments were significantly better than for 15-mm segments or a single section. Similar excellent correlations and agreement were observed for actual and ICUS-derived end-systolic volumes using 5-, 10-, or 15-mm segments. The ICUS-derived EF correlated very well with actual EF with a small measurement error of 3.91 +/- 2.59% for 5-mm or 4.13 +/- 2.79% for 10-mm segments but a significantly greater measurement error for 15-mm segments (5.35 +/- 3.76%) or single sections (14.8 +/- 12.2%). The presence of LV infarction or aneurysm did not significantly influence the accuracy of ICUS calculations for segmental heights < or = 10 mm. Application in intact animals demonstrated a good correlation between stroke volume measured by ICUS and by thermodilution or flowmeter. ICUS-derived LV volumes correlated well with biplane angiographic volumes, with a tendency toward underestimation. There was no significant difference between ICUS-determined LV EF and EF determined by angiography. CONCLUSIONS Intracardiac echocardiography accurately measures LV volumes and global systolic function in both regularly shaped and distorted left ventricles. This technique directly and continuously visualizes circumferential LV endocardium and wall thickness without contrast agents or geometric assumptions for calculation of LV volume. Thus, it should be particularly useful in patients at high risk for contrast-related complications or distorted LV shapes in which geometric assumptions may not be valid.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using a 10-MHz Ultrasound Catheter

Background Our objective was to examine the accuracy of intracardiac ultrasound (ICUS) measurement of left ventricular (LV) volumes and ejection fraction (EF) using a 10-MHz ultrasound catheter. ICUS can image the LV in cross sections at all levels along the long axis with a transducer mounted on the tip of a catheter. Sequential serial LV cross-sectional images can be obtained during cardiac c...

متن کامل

Imaging of wall motion coupled with blood flow velocity in the heart and vessels in vivo: a feasibility study.

The mechanical property and geometry changes as a result of cardiovascular disease affect both the wall motion and blood flow in the heart and vessels, whereas the latter two are also coupled and therefore continuously influence one another. Simultaneous and registered imaging of both cardiovascular wall motion and blood velocity may thus contribute to more complete computational models of card...

متن کامل

Doppler-Derived Myocardial Performance Index in Healthy Children in Shiraz

Background: Assessment of myocardial function is essential in heart disease, but in regard to systolic and diastolic functions such evaluation has limitation. Ejection fraction is difficult to assess in abnormally-shaped ventricles, and diastolic inflow velocity pattern may be fused because of tachycardia. Objective: A myocardial performance index (MPI) or Tei index has been developed for adult...

متن کامل

Quantitative 3-dimensional echocardiography for accurate and rapid cardiac phenotype characterization in mice.

BACKGROUND Insufficient techniques exist for rapid and reliable phenotype characterization of genetically manipulated mouse models of cardiac dysfunction. We developed a new, robust, 3-dimensional echocardiography (3D-echo) technique and hypothesized that this 3D-echo technique is as accurate as magnetic resonance imaging (MRI) and histology for assessment of left ventricular (LV) volume, eject...

متن کامل

The application of discriminant analysis in differentiation of fibroadenoma and ductal carcinoma of breast tissue using ultrasound velocity measurement

Background: Ultrasound propagation velocity was measured experimentally in normal, fibroadenoma and ductal carcinoma breast tissues, in order to distinguish normal breast tissue from tumors. Materials and methods: In quantitative measurements of ultrasound velocity, 403 breast tissue images were selected, comprising 130 normal breast tissue, 130 fibroadenoma, and 143 ductal carcinoma tumors. Th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 90 3  شماره 

صفحات  -

تاریخ انتشار 1994