Reference population and marathon runner sera assessed by highly sensitive cardiac troponin T and commercial cardiac troponin T and I assays.
نویسندگان
چکیده
BACKGROUND Endurance exercise can increase cardiac troponin (cTn) concentrations as high as those seen in cases of minor myocardial infarction. The inability of most cTn assays to reliably quantify cTn at very low concentrations complicates a thorough data analysis, and the clinical implications of such increases remain unclear. The application of recently developed highly sensitive cTn immunoassays may help resolve these problems. METHODS We evaluated the precommercial highly sensitive cardiac troponin T (hs-cTnT) assay from Roche Diagnostics and the Architect cardiac troponin I (cTnI-Architect) assay from Abbott Diagnostics by testing samples from a reference population of 546 individuals and a cohort of 85 marathon runners. We also measured the samples with the current commercial cTnT assay for comparison. RESULTS Although the hs-cTnT and cTnI-Architect assays were capable of measuring cTn concentrations at low concentrations (<0.01 microg/L), only the hs-cTnT assay demonstrated a CV of <10% at the 99th percentile of the reference population and a near-gaussian distribution of the measurements. After a marathon, 86% of the runners had cTnT concentrations greater than the 99th percentile with the hs-cTnT assay, whereas only 45% of the runners showed increased concentrations with the current cTnT assay. cTn concentrations remained significantly increased the day after the marathon. A multiple regression analysis demonstrated marathon experience and age to be significant predictors of postmarathon cTn concentrations (P < 0.05). CONCLUSIONS The hs-cTnT assay was the only assay tested with a performance capability sufficient to detect cTn concentrations in healthy individuals. The number of runners with increased cTn concentrations after a marathon depends highly on an assay's limit of detection (LOD). The assay with the lowest LOD, the hs-cTnT assay, showed that almost all runners had increased cTn concentrations. The clinical implications of these findings require further investigation.
منابع مشابه
Analysis of the relation between coping ways with stress and Cardiac Biomarker Troponin I in coronary heart disease patients
Introduction: Coping ways with stress in coronary heart disease patients can lead to significant changes in levels of Cardiac Biomarker Troponin I, but researchers had not explored it empirically. So, the main objective of this study was to identify the relationship between coping ways with stress and Cardiac Biomarker Troponin I and also, finding coping ways that predict changes in the concent...
متن کاملValues of troponin T and myoglobin predictive of non-cardiac ischemia in rats
Objective(s):Biochemical markers are important for the timely diagnosis and follow-up of ischemic events. Most of the markers have been previously studied in the context of cardiac ischemia. However, research on markers of non-cardiac events has been insufficient. Therefore, we investigated the relationship between troponin and myoglobin which are commonly used markers of cardiac ischemia, in n...
متن کاملCorrelation between the Level of Creatinine, Serum Cardiac Troponines and Left Ventricle Function Tests in Patients with Chronic Renal Diseases without Acute Coronary Syndrome
Background and Objectives: The aim of this study was to survey the relationship between the level of creatinine,cardiac troponins serum and the function of the left ventricle in patients with kidney insufficiency,without acute coronary syndrome. Materialsand Methods:The sample was150 patients with nondialysis chronic kidney disease without acute coronary syndrome, hospitalized at I...
متن کاملDetermination of 19 cardiac troponin I and T assay 99th percentile values from a common presumably healthy population.
BACKGROUND Between-assay comparability of 99th percentiles for cardiac troponin concentrations has not been assessed systematically in a single population for a large number of assays. METHODS We determined 99th percentiles for 19 cardiac troponin assays in heparin plasma samples from a population of 272 and 252 presumably healthy males and females, respectively. The assays evaluated included...
متن کاملVariation of cardiac troponin I and T measured with sensitive assays in emergency department patients with noncardiac chest pain.
BACKGROUND New-generation high-sensitivity assays for cardiac troponin have lower detection limits and less imprecision than earlier assays. Reference 99th-percentile cutoff values for these new assays are also lower, leading to higher frequencies of positive test results. When cardiac troponin concentrations are minimally increased, serial testing allows discrimination of myocardial infarction...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 55 1 شماره
صفحات -
تاریخ انتشار 2009