Use of pulse pressure method for estimating total arterial compliance in vivo.
نویسندگان
چکیده
We determined total arterial compliance from pressure and flow in the ascending aorta of seven anesthetized dogs using the pulse pressure method (PPM) and the decay time method (DTM). Compliance was determined under control and during occlusion of the aorta at four different locations (iliac, renal, diaphragm, and proximal descending thoracic aorta). Compliance of PPM gave consistently lower values (0.893 ± 0.015) compared with the compliance of DTM (means ± SE; r = 0.989). The lower compliance estimates by the PPM can be attributed to the difference in mean pressures at which compliance is determined (mean pressure, 81.0 ± 3.6 mmHg; mean diastolic pressure, over which the DTM applies, 67.0 ± 3.6 mmHg). Total arterial compliance under control conditions was 0.169 ± 0.007 ml/mmHg. Compliance of the proximal aorta, obtained during occlusion of the proximal descending aorta, was 0.100 ± 0.007 ml/mmHg. Mean aortic pressure was 80.4 ± 3.6 mmHg during control and 102 ± 7.7 mmHg during proximal descending aortic occlusion. From these results and assuming that upper limbs and the head contribute as little as the lower limbs, we conclude that 60% of total arterial compliance resides in the proximal aorta. When we take into account the inverse relationship between pressure and compliance, the contribution of the proximal aorta to the total arterial compliance is even more significant.
منابع مشابه
A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis
Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...
متن کاملEvaluation of aortic compliance in humans.
The central aorta acts as a compliant tube that buffers and conducts pulsatile ventricular output (7) and contributes mostly to total compliance of the arterial tree. The mathematical model introduced by O. Frank (7) describing pulse wave propagation and arterial mechanical properties assumes that the arterial tree is an elastic chamber (windkessel) in which the diastolic pressure decays expone...
متن کاملMeasurement of total pulmonary arterial compliance using invasive pressure monitoring and MR flow quantification during MR-guided cardiac catheterization.
Pulmonary hypertensive disease is assessed by quantification of pulmonary vascular resistance. Pulmonary total arterial compliance is also an indicator of pulmonary hypertensive disease. However, because of difficulties in measuring compliance, it is rarely used. We describe a method of measuring pulmonary arterial compliance utilizing magnetic resonance (MR) flow data and invasive pressure mea...
متن کاملPresentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall
Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the substitution of the blood pressure changes in the central arteries such as carotid with the blood pressure changes in the brachial results in error in the blood...
متن کاملAortic function quantified: the heart's essential cushion.
Arterial compliance is mainly determined by the elasticity of proximal large-conduit arteries of which the aorta is the largest contributor. Compliance forms an important part of the cardiac load and plays a role in organ (especially coronary) perfusion. To follow local changes in aortic compliance, as in aging, noninvasive determination of compliance distribution would be of great value. Our g...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- American journal of physiology. Heart and circulatory physiology
دوره 276 2 شماره
صفحات -