Using image-based regression to acquire freehand 3D ultrasound
نویسندگان
چکیده
In freehand 3D ultrasound, a position sensor is attached to the probe of a 2D ultrasound machine. The resulting 3D data permits flexible visualisation and more accurate volume measurement than can be achieved using 2D B-scans alone; however the use of the position sensor can be inconvenient for the clinician. The objective is thus to replace the sensor with a technique for estimating the probe trajectory based on the B-scan images themselves. One such technique exists, based on decorrelation algorithms. This report presents an alternative approach based on linear regression of the echo envelope intensity signal. A probabilistic analysis of the speckle characteristics of the ultrasound signal leads to a linear model on which the regression algorithm is based. The gradient parameter of this model is shown to be directly related to probe motion. The viability of the new approach is demonstrated through simulations, and in vitro and in vivo experiments.
منابع مشابه
Backward-Warping Ultrasound Reconstruction for Improving Diagnostic Value and Registration
Freehand 3D ultrasound systems acquire sets of B-Mode ultrasound images tagged with position information obtained by a tracking device. For both further processing and clinical use of these ultrasound slice images scattered in space, it is often required to reconstruct them into 3D-rectilinear grid arrays. We propose new efficient methods for this so-called ultrasound spatial compounding using ...
متن کاملReconstruction of freehand 3D ultrasound based on kernel regression
INTRODUCTION Freehand three-dimensional (3D) ultrasound has the advantages of flexibility for allowing clinicians to manipulate the ultrasound probe over the examined body surface with less constraint in comparison with other scanning protocols. Thus it is widely used in clinical diagnose and image-guided surgery. However, as the data scanning of freehand-style is subjective, the collected B-sc...
متن کاملRotational Motion in Sensorless Freehand 3d Ultrasound
Freehand 3D ultrasound can be acquired without a position sensor by using image-based positioning methods. In-plane motion can be tracked using image registration between nearby images. Elevational probe motion can be determined from the decorrelation between images. However, a freehand scan involves rotational as well as translational motion, and this affects the decorrelation. If this effect ...
متن کاملImage-Based Method for In-Vivo Freehand Ultrasound Calibration
For freehand ultrasound systems, a calibration method is necessary to locate the position and orientation of a 2D B-mode ultrasound image plane with respect to a position sensor attached to the transducer. In addition, the acquisition time discrepancy between the position measurements and the image frames has the be computed. We developed a new method that adresses both of these problems, based...
متن کاملCorrection of Probe Pressure Artifacts in Freehand 3 D Ultrasound — Initial Results
We present an algorithm which combines non-rigid image-based registration and conventional position sensing to correct probe-pressure-induced registration errors in freehand three-dimensional (3D) ultrasound volumes. The local accuracy of image-based registration enables the accurate freehand acquisition of high resolution (> 15MHz) 3D ultrasound data, opening the way for 3D musculoskeletal exa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2002