Ischemia modified albumin: does it change during pneumoperitoneum in robotic prostatectomies?
نویسندگان
چکیده
BACKGROUND The unique positioning of the patient at steep Trendelenburg with prolonged and increased intra-abdominal pressure (IAP) during robotic radical prostatectomy may increase the risk of splanchnic ischemia. We aimed to investigate the acute effects of IAP and steep Trendelenburg position on the level of ischemia modified albumin (IMA) and to test if serum IMA levels might be used as a surrogate marker for possible covert ischemia during robotic radical prostatectomies. PATIENTS AND METHODS Fifty ASA I-II patients scheduled for elective robotic radical prostatectomy were included in this investigation. EXCLUSION CRITERIA The patients were excluded from the study when an arterial cannulation could not be accomplished, if the case had to be converted to open surgery or if the calculated intraoperative bleeding exceeded 300ml. All the patients were placed in steep (45 degrees) Trendelenburg position following trocar placement. Throughout the operation the IAP was maintained between 11-14mmHg. Mean arterial blood pressure (MAP), cardiac output (CO) were continuously monitored before the induction and throughout the surgery. Blood gases, electrolytes, urea, creatinine, alanine transferase (ALT), aspartate transferase (AST) were recorded. Additionally, IMA levels were measured before, during and after surgery. RESULTS (1) MAP, CO, lactate and hemoglobin (Hb) did not significantly change in any period of surgery (p>0.05); (2) sodium (p<0.01), potassium (p<0.05) and urea (p<0.05) levels decreased at postoperative period, and no significant changes at creatinine, AST, ALT levels were observed in these patients; (3) At the end of surgery (180 min) pCO2, pO2, HCO3 and BE did not change compared to after induction values (p>0.05) but mild acidosis was present in these patients (p<0.01 vs. after induction); (4) IMA levels were found to be comparable before induction (0.34±0.04), after induction (0.31±0.06) and at the end of surgery (0.29±0.05) as well. CONCLUSION We did not demonstrate any significant mesenteric-splanchnic ischemia which could be detected by serum IMA levels during robotic radical prostatectomies performed under steep Trendelenburg position and when IAP is maintained in between 11-14 mmHg.
منابع مشابه
Clinical Significance of Ischemia-Modified Albumin in the Diagnosis of Doxorubicin-Induced Myocardial Injury in Breast Cancer Patients
BACKGROUND Ischemia-modified albumin is an altered serum albumin that forms under conditions of oxidative stress, a state also associated with doxorubicin-induced myocardial injury. OBJECTIVE The aim of this study was to better assess diagnostic and prognostic significance of ischemia-modified albumin in patients with breast cancer undergoing doxorubicin chemotherapy. METHODS Blood samples ...
متن کاملDoes Heart Affect Peripheral Vascular Resistance Following Myocardial Ischemia and Reperfusion?
Objective(s) The aim of this study was to investigate the overall effect of cardiac vasoactive factors during coronary occlusion and reperfusion on peripheral vascular tone, using a sequential isolated rabbit heart-ear perfusion model. Materials and Methods Isolated ears were perfused with the effluent of isolated hearts subjected to ischemia (30 min) and reperfusion (180 min, n=6). The comp...
متن کاملTransition from open to robotic-assisted radical prostatectomy: 7 years experience at Hackensack University Medical Center
Background and objective Open radical prostatectomy (ORP) is the standard approach for the surgical management of localized prostate cancer. The steep learning curve for laparoscopic prostatectomy poses a challenge for surgeons with minimal laparoscopic experience. As robotic-assisted surgery becomes more prevalent in the urologic community, there appears to be an increasing interest in robotic...
متن کاملPower injection of renewable energy sources using modified model predictive control
This paper presents a simple model predictive control (MPC) approach to control the power injection system (PIS) for renewable energy applications. A DC voltage source and a single-phase inverter that is connected to the grid by an LCL filter form the PIS. Grid voltage is considered a disturbance for the system. For eliminating this disturbance, a modified model is proposed. It is usual to ...
متن کاملPower injection of renewable energy sources using modified model predictive control
This paper presents a simple model predictive control (MPC) approach to control the power injection system (PIS) for renewable energy applications. A DC voltage source and a single-phase inverter that is connected to the grid by an LCL filter form the PIS. Grid voltage is considered a disturbance for the system. For eliminating this disturbance, a modified model is proposed. It is usual to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- International braz j urol : official journal of the Brazilian Society of Urology
دوره 42 1 شماره
صفحات -
تاریخ انتشار 2016