A study of functional anatomy of aortic-mitral valve coupling using 3D matrix transesophageal echocardiography.

نویسندگان

  • Federico Veronesi
  • Cristiana Corsi
  • Lissa Sugeng
  • Victor Mor-Avi
  • Enrico G Caiani
  • Lynn Weinert
  • Claudio Lamberti
  • Roberto M Lang
چکیده

BACKGROUND Mitral and aortic valves are known to be coupled via fibrous tissue connecting the two annuli. Previous studies evaluating this coupling have been limited to experimental animals using invasive techniques. The new matrix array transesophageal transducer provides high-resolution real-time 3D images of both valves simultaneously. We sought to develop and test a technique for quantitative assessment of mitral and aortic valve dynamics and coupling. METHODS AND RESULTS Matrix array transesophageal (Philips iE33) imaging was performed in 24 patients with normal valves who underwent clinically indicated transesophageal echocardiography. Custom software was used to detect and track the mitral and aortic annuli in 3D space throughout the cardiac cycle, allowing automated measurement of changes in mitral and aortic valve morphology. Mitral annulus surface area and aortic annulus projected area changed reciprocally over time. Mitral annulus surface area was 8.0+/-2.1 cm(2) at end-diastole and decreased to 7.7+/-2.1 cm(2) in systole, reaching its maximum (10.0+/-2.2 cm(2)) at mitral valve opening. Aortic annulus projected area was 4.1+/-1.2 cm(2) at end-diastole, then increased during isovolumic contraction reaching its maximum (4.8+/-1.3 cm(2)) in the first third of systole and its minimum (3.6+/-1.0 cm(2)) during isovolumic relaxation. The angle between the mitral and aortic annuli was maximum (136+/-13 degrees ) at end-diastole and decreased to its minimum value (129+/-11 degrees ) during systole. CONCLUSIONS This is the first study to report quantitative 3D assessment of the mitral and aortic valve dynamics from matrix array transesophageal images and describe the mitral-aortic coupling in a beating human heart. This ability may have impact on patient evaluation for valvular surgical interventions and prosthesis design.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aortic regurgitation during systolic-phase accompanied by mitral regurgitation in patients with continuous-flow left ventricular assist device.

results along with previous studies by the same group are relevant to the scientific community for several reasons. Three-dimensional echocardiography and software developments open a new field of research on cardiac physiology and pathological conditions previously limited to experimental animal models. Continuous development of new therapeutic surgical and interventional devices challenges no...

متن کامل

Evaluation of transesophageal echocardiography in detecting cardiac sources of emboli in ischemic stroke patients

  Background: Embolus is one of the causes of ischemic stroke that can be due to cardiac sources such as valvular heart diseases and atrial fibrillation and atheroma of the aorta. Transesophageal echocardiography (TEE) is superior in identifying potential cardiac sources of emboli. Due to insufficient data on TEE findings in ischemic stroke in Iran, the present study was done to evaluate TEE in...

متن کامل

سودوآنوریسم فیستولیزه شده فیبروز بین دریچه ای میترال و آئورت در یک بیمار پس از عمل جراحی بای پس عروق کرونر

Pseudoaneurysm is a rare condition in the region of the fibrous body between the mitral and aortic valve, the mitral-aortic intervalvular fibrosa (MAIVF), that has been reported as a sequela of endocarditis and surgical trauma. MAIVF rarely occurs on native aortic valve after infective endocarditis (IE). It is often fatal because of its rapid progress, high rates of rupture and recurrence, and ...

متن کامل

Dynamic three-dimensional reconstruction of the heart by transesophageal echocardiography.

OBJECTIVE To evaluate echocardiography accuracy in performing and obtaining images for dynamical three-dimensional (3D) reconstruction. METHODS Three-dimensional (3D) image reconstruction was obtained in 20 consecutive patients who underwent transesophageal echocardiography. A multiplanar 5 MHz transducer was used for 3D reconstruction. RESULTS Twenty patients were studied consecutively. Th...

متن کامل

Role of modern 3D echocardiography in valvular heart disease

Three-dimensional (3D) echocardiography has been conceived as one of the most promising methods for the diagnosis of valvular heart disease, and recently has become an integral clinical tool thanks to the development of high quality real-time transesophageal echocardiography (TEE). In particular, for mitral valve diseases, this new approach has proven to be the most unique, powerful, and convin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Cardiovascular imaging

دوره 2 1  شماره 

صفحات  -

تاریخ انتشار 2009