Load Frequency Control Using Classical Controller in An Isolated Single Area and Two Area Reheat Thermal Power System

نویسندگان

  • Kallol Das
  • Sharmistha Sharma
چکیده

In this paper, Load Frequency Control (LFC) of isolated single area and two-area re-heat inter-connected thermal power system has been carried out by the classical controllers i.e. I, PI and PID; and implemented on the system at 1% step load perturbation under nominal loading conditions. The system responses have been simulated in MATLAB R2010a. Responses of deviation in frequencies, deviation in tie-line power and choosing the optimum controller (i.e. better among I, PI & PID controllers) gain values (i.e. ) to have better dynamic responses of the system have been plotted, keeping in view the characteristics such as rise time, settling time, oscillations & peak overshoot. Thus, on the basis of these responses, the dynamic performance of the system has been studied. Effect of variation in regulation parameter (R) and also step load perturbations is simulated for different values. The simulation results indicate that better control performance in terms of overshoot and settling time can be achieved by choosing PID among the other considered classical controllers. Keywords— Automatic Generation Control, Controllers (I, PI & PID), Frequency Deviation, Generation Rate Constraints, Load Frequency Control, Single Area Power System, Two Area Interconnected Power System, Tie-line Power Deviation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Robust Discrete FuzzyP+FuzzyI+FuzzyD Load Frequency Controller for Multi-Source Power System in Restructuring Environment

In this paper a fuzzy logic (FL) based load frequency controller (LFC) called discrete FuzzyP+FuzzyI+FuzzyD (FP+FI+FD) is proposed to ensure the stability of a multi-source power system in restructured environment. The whale optimization algorithm (WOA) is used for optimum designing the proposed control strategy to reduce fuzzy system effort and achieve the best performance of LFC task. Further...

متن کامل

Dynamic Response Analysis of Automatic Generation Control in a 2 - Area ( Reheat & Non - Reheat ) Interconnected Power System and a Scheme for Improvement of Response for the Same

Abstract: In the present work, we focus on the study of dynamic behavior of an interconnected two-area power system and a scheme for improvement of response for the same. Here, two-area system with one non-reheat thermal units & one reheat thermal units is considered. The frequency and tie-line power deviation of two units are studied using MATLAB-SIMULINK in continuous time domain and also in ...

متن کامل

Load Frequency Control for a Two-area Interconnected Power System by Using Sliding Mode Controller

This paper presents the usage of sliding mode Control algorithm for the load frequency control in power systems. A sliding mode based load frequency controller is applied to a two-area power system. Non-reheat and reheat Thermal turbines are distributed in these two areas respectively. The nonlinearities such as governor dead band and generation rate constraint are included in the block diagram...

متن کامل

Control Performance Standard based Load Frequency Control of a two area Reheat Interconnected Power System considering Governor Dead Band nonlinearity using Fuzzy Neural Network

The frequency control of reheat interconnected two area power systems are mainly characterized by non-linearity and uncertainty. A hybrid neural network and fuzzy control is proposed for load frequency control in the power systems considering governor dead band (GDB) non-linearity. Fuzzy with neural network is employed to forecast the control input requirement and system's future output, b...

متن کامل

Area Requirement based Load Frequency Controller using Artificial Bee Colony Algorithm for a Two Area Interconnected Power System with GT Unit

This paper proposes a design of Artificial Bee Colony (ABC) algorithm based Proportional plus Integral controller using Area Requirement (AR) Criterion for the Load Frequency Control of a two area multi unit interconnected thermal reheat power system without and with Gas Turbine unit. The system was simulated and the output responses of the frequency deviations, tie-line power deviation and con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012