Determination of human ventricular repolarization by noncontact mapping: validation with monophasic action potential recordings.
نویسندگان
چکیده
BACKGROUND Noncontact mapping (NCM) has not been validated as a clinical technique to measure ventricular repolarization. We used NCM to determine repolarization characteristics by analysis of reconstructed unipolar electrograms (UEs) at the same sites as monophasic action potential (MAP) recordings in the human ventricle. METHODS AND RESULTS MAPs were recorded from a total of 355 beats at 46 sites in the left or right ventricle of 9 patients undergoing ablation of ventricular tachycardia guided by NCM (EnSite system). Measurements were made during sinus rhythm, constant right ventricular pacing, and ventricular extrastimuli during restitution-curve construction. The EnGuide locator signal was used to document MAP catheter locations on the endocardial geometry. UE-determined activation-recovery interval (ARI) measured at the maximum derivative of the T wave (Wyatt method) and the minimum derivative of the positive T wave (alternative method) was correlated with MAP measured at 90% repolarization (MAP90%) at the same sites. ARI correlated with MAP90% during steady state by the Wyatt method (r=0.83, P<0.001) and the alternative method (r=0.94, P<0.001). Restitution curves constructed from MAP and UE data exhibited the same characteristics, with a mean correlation coefficient of 0.95 (range, 0.90 to 0.99, P<0.001). The error between ARI and MAP90% was greater over a shorter diastolic coupling interval but was not influenced by distance of the sampling site from the multielectrode array. CONCLUSIONS NCM accurately determines steady-state and dynamic endocardial repolarization in humans. Global, high-density, NCM data could be used to characterize abnormalities of human ventricular repolarization.
منابع مشابه
Global dynamic coupling of activation and repolarization in the human ventricle.
BACKGROUND The ability to determine spatial and dynamic changes in ventricular repolarization may help to understand arrhythmogenic mechanisms in humans. We hypothesized that noncontact mapping could be used to investigate global activation-repolarization coupling in the human ventricle during steady state and premature extrastimulation. METHODS AND RESULTS Activation-recovery intervals (ARIs...
متن کاملMonophasic action potential mapping in human subjects with normal electrocardiograms: direct evidence for the genesis of the T wave.
T wave concordance in the normal human electrocardiogram (ECG) generally is explained by assuming opposite directions of ventricular depolarization and repolarization; however, direct experimental evidence for this hypothesis is lacking. We used a contact electrode catheter to record monophasic action potentials (MAPs) from 54 left ventricular endocardial sites during cardiac catheterization (s...
متن کاملCharacterization of ventricular fibrillation based on monophasic action potential morphology in the human heart.
BACKGROUND Recent studies examining mechanisms of defibrillation have focused on prolongation of graded cellular response duration during refractory period stimulation. This mechanism assumes that defibrillation shocks interact with ventricular cells during the process of repolarization. METHODS AND RESULTS To test this assumption, we examined monophasic action potentials (MAPs) from 171 epis...
متن کاملGlobal endocardial electrical restitution in human right and left ventricles determined by noncontact mapping.
OBJECTIVES This study was aimed at evaluating global characteristics of electrical restitution in the human ventricle using noncontact mapping. BACKGROUND Steep action potential restitution (slope >1) and conduction velocity (CV) restitution have been linked with propensity to ventricular fibrillation, but clinical measurement of global electrical restitution had not been feasible. METHODS ...
متن کاملStretch-induced regional mechanoelectric dispersion and arrhythmia in the right ventricle of anesthetized lambs.
Regional mechanical and electrophysiological changes accompany most ventricular arrhythmias and, it has been suggested, by mechanoelectric feedback. We hypothesized that an intervention producing regional mechanical dispersion was associated with regional, proarrhythmic electrical dispersion and studied the regional mechanoelectric feedback in the right ventricle (RV) of anesthetized lambs. Ten...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 110 11 شماره
صفحات -
تاریخ انتشار 2004