چکیده

BACKGROUND Transcatheter pulmonary valve implantation using the Melody valve has emerged as an important therapy for the treatment of postoperative right ventricular outflow tract dysfunction. Melody-in-bioprosthetic valves (BPV) is currently considered an off-label indication. We review the combined experience with transcatheter pulmonary valve implantation within BPVs from 8 centers in the United States and discuss technical aspects of the Melody-in-BPV procedure. METHODS AND RESULTS A total of 104 patients underwent Melody-in-BPV in the pulmonary position at 8 US centers from April 2007 to January 2012. Ten different types of BPVs were intervened on, with Melody valve implantation at the intended site in all patients. Following Melody valve implant, the peak right ventricle-to-pulmonary artery gradient decreased from 38.7 ± 16.3 to 10.9 ± 6.7 mm Hg (P<0.001), and the right ventricular systolic pressure fell from 71.6 ± 21.7 to 46.7 ± 15.9 mm Hg (P<0.001). There was no serious procedural morbidity, and no deaths related to the catheterization or implant. At a median follow-up of 12 months (1-46 months), no patients had more than mild regurgitation, and 4 had a mean right ventricular outflow tract gradient ≥30 mm Hg. During follow-up, there were 2 stent fractures, 3 cases of endocarditis (2 managed with surgical explant), and 2 deaths that were unrelated to the Melody valve. CONCLUSIONS Transcatheter pulmonary valve implantation using the Melody valve within BPVs can be accomplished with a high rate of success, low procedure-related morbidity and mortality, and excellent short-term results. The findings of this preliminary multicenter experience suggest that the Melody valve is an effective transcatheter treatment option for failed BPVs.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stent fracture, valve dysfunction, and right ventricular outflow tract reintervention after transcatheter pulmonary valve implantation: patient-related and procedural risk factors in the US Melody Valve Trial.

BACKGROUND Among patients undergoing transcatheter pulmonary valve (TPV) replacement with the Melody valve, risk factors for Melody stent fracture (MSF) and right ventricular outflow tract (RVOT) reintervention have not been well defined. METHODS AND RESULTS From January 2007 to January 2010, 150 patients (median age, 19 years) underwent TPV implantation in the Melody valve Investigational De...

متن کامل

Aortic Valve Replacement in Children and Young Adults.

SEE PAGE 2858 T he perfect heart valve substitute has not yet been developed and matching the patient to existing options to optimize survival and reduce valve-related complications remains challenging. The choices for aortic valve replacement (AVR) are mechanical valves, bioprosthetic valves, and biological valves such as aortic valve homograft and the Ross procedure (pulmonary autograft). The...

متن کامل

Trans-catheter Bioprosthetic Heart Valve Implantation in Iran (Tehran Heart Centre Experience)

Introduction: With the development of interventional cardiology in the world, in addition to coronary and aortic diseases, the treatment of heart valve diseases through catheters has recently begun. The treatment of aortic stenosis (which was only possible with open surgery and valve replacement) was first performed in the world in 2002 by Alain Cribier in France with catheter insertion of the ...

متن کامل

Percutaneous tricuspid valve replacement in congenital and acquired heart disease.

OBJECTIVES This study sought to describe the first human series of percutaneous tricuspid valve replacements in patients with congenital or acquired tricuspid valve (TV) disease. BACKGROUND Percutaneous transcatheter heart valve replacement of the ventriculoarterial (aortic, pulmonary) valves is established. Although there are isolated reports of transcatheter atrioventricular heart valve rep...

متن کامل

Transcatheter valve-in-valve implantation for failed bioprosthetic heart valves.

BACKGROUND The majority of prosthetic heart valves currently implanted are tissue valves that can be expected to degenerate with time and eventually fail. Repeat cardiac surgery to replace these valves is associated with significant morbidity and mortality. Transcatheter heart valve implantation within a failed bioprosthesis, a "valve-in-valve" procedure, may offer a less invasive alternative. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 5 6  شماره 

صفحات  -

تاریخ انتشار 2012