Fast isotropic volumetric coronary MR angiography using free-breathing 3D radial balanced FFE acquisition.
نویسندگان
چکیده
A shortcoming of current coronary MRA methods with thin-slab 3D acquisitions is the time-consuming examination necessitated by extensive scout scanning and precise slice planning. To improve ease of use and cover larger parts of the anatomy, it appears desirable to image the entire heart with high spatial resolution instead. For this purpose, an isotropic 3D-radial acquisition was employed in this study. This method allows undersampling of k-space in all three spatial dimensions, and its insensitivity to motion enables extended acquisitions per cardiac cycle. We present initial phantom and in vivo results obtained in volunteers that demonstrate large volume coverage with high isotropic spatial resolution. We were able to visualize all major parts of the coronary arteries retrospectively from the volume data set without compromising the image quality. The scan time ranged from 10 to 14 min during free breathing at a heart rate of 60 bpm, which is comparable to that of a thin-slab protocol comprising multiple scans for each coronary artery.
منابع مشابه
Navigator-Gated Whole Heart Coronary MRI with 3D isotropic Double Echo TrueFISP UTE
Introduction Coronary MRA provides a non-invasive approach for the detection of coronary artery disease. Previous works have shown that whole heart 3D radial techniques simplify the scanning procedure with no compromise in image quality [1-4]. Ultra-short Echo Time (UTE) MRI allows for the detection of short T2 components (T2 of the order of 100 μs) in tissue before they have decayed [5, 6]. Th...
متن کاملSimulation Tool for k-Space Reordering in Free-Breathing Navigator-Gated 3D Coronary MRA
In coronary MR angiography (MRA) breathing motion during data acquisition may result in image artifacts. One solution is the use of MR navigators to gate to the respiratory cycle, but the use of narrow gating windows often lead to prolonged/time inefficient scans. Therefore sophisticated k-space reordering techniques 1, 2 have been proposed to reduce motion artifacts in free-breathing navigator...
متن کاملBreath-hold imaging of the coronary arteries using quiescent-interval slice-selective (qiss) magnetic resonance angiography - pilot study at 1.5 tesla and 3 tesla
BACKGROUND Coronary magnetic resonance angiography (MRA) is usually obtained with a free-breathing navigator-gated 3D acquisition. Our aim was to develop an alternative breath-hold approach that would allow the coronary arteries to be evaluated in a much shorter time and without risk of degradation by respiratory motion artifacts. For this purpose, we implemented a breath-hold, non-contrast-enh...
متن کاملQualitative and Quantitative Assessment of Isotropic Ankle Magnetic Resonance Imaging: Three-Dimensional Isotropic Intermediate-Weighted Turbo Spin Echo versus Three-Dimensional Isotropic Fast Field Echo Sequences
OBJECTIVE To compare the image quality of volume isotropic turbo spin echo acquisition (VISTA) imaging method with that of the three-dimensional (3D) isotropic fast field echo (FFE) imaging method applied for ankle joint imaging. MATERIALS AND METHODS MR imaging of the ankles of 10 healthy volunteers was performed with VISTA and 3D FFE sequences by using a 3.0 T machine. Two radiologists retr...
متن کاملAccelerated isotropic resolution 3D image-based navigators for coronary MR angiography
PURPOSE To develop a method for acquiring whole-heart 3D image-based navigators (iNAVs) with isotropic resolution for tracking and correction of localized motion in coronary magnetic resonance angiography (CMRA). METHODS To monitor motion in all regions of the heart during a free-breathing scan, a variable-density cones trajectory was designed to collect a 3D iNAV every heartbeat in 176 ms wi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 52 1 شماره
صفحات -
تاریخ انتشار 2004