Blood Flow, Negative Pressure, and Hemolysis During Hemodialysis.

نویسندگان

  • Zbylut J Twardowski
  • Jimmy D Haynie
  • Harold L Moore
چکیده

Blood flow, measured by an ultrasound flowmeter, and the extent of hemolysis were assessed during a single, routine dialysis in 100 patients. Before and after the hemodialysis session, blood was drawn for measurements of haptoglobin (HPT), hemoglobin (HGB), albumin (ALB), and lactate dehydrogenase (LDH). The average values were as follows: pump speed 510 mL/ min, real blood flow 422 mL/min, arterial chamber pressure -350 mm Hg, and venous chamber pressure 279 mm Hg. Haptoglobin concentrations were higher in patients with central vein catheters compared to patients with arteriovenous access. The meaning of this finding is unclear. Mean HPT concentrations increased significantly less during hemodialysis (2.37%) than concentrations of ALB (11.3%), HGB (9.17%), and LDH (18.2%), indicating that some hemolysis is present in all dialyses. In dialyses with arterial chamber pressures more negative than -350 the median concentration of ALB (8.70%) increased significantly more than the median concentration of HGB (7.99%). This indicates significantly more hemolysis in dialyses with more negative pressures compared to those with less negative arterial chamber pressures. Median LDH increased more in dialyses with more negative prepump chamber pressures (16.19% vs 13.78%), but not significantly; however, LDH increases were significantly higher than either HGB or ALB, thus indicating significantly more hemolysis in dialyses with more negative pressures compared to those with less negative arterial chamber pressures. Erythropoietin dose was not significantly different in patients dialyzed with more or less negative arterial chamber pressures (17 645 ± 1226 U/week vs 16 308 ± 1506 U/week). We conclude that dialyses with negative arterial chamber pressures greater than -350 mm Hg cause slightly higher hemolysis than dialyses with less negative arterial chamber pressures, but this increased hemolysis is not associated with an increased requirement of erythropoietin dose. Whether this increased hemolysis is of clinical significance is uncertain.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه فشار خون بیماران همودیالیزی در دو وضعیت خوابیده به پشت و نیمه نشسته

  ABSTRACT   Background and Aim: Hemodialysis is the most common method of treatment for chronic renal insufficiency an advanced and unretrieveable disorder. Hemodialysis has some complications on which the position of the patient can be effective. Routinely, patients are placed on supine position during hemodialysis, but they are not comfortable in this position, and most of them would like to...

متن کامل

An extracorporeal carbon dioxide removal (ECCO2R) device operating at hemodialysis blood flow rates

BACKGROUND Extracorporeal carbon dioxide removal (ECCO2R) systems have gained clinical appeal as supplemental therapy in the treatment of acute and chronic respiratory injuries with low tidal volume or non-invasive ventilation. We have developed an ultra-low-flow ECCO2R device (ULFED) capable of operating at blood flows comparable to renal hemodialysis (250 mL/min). Comparable operating conditi...

متن کامل

Effects of hemodialysis on cerebral circulation evaluated by transcranial Doppler ultrasonography.

BACKGROUND AND PURPOSE The effects of hemodialysis on the cerebral circulation of humans and the correlation between changes in blood flow velocity in the basal cerebral arteries and those of several physiological variables influenced by hemodialysis have been inadequately studied. METHODS Blood flow velocities were obtained from the middle cerebral artery and the basilar artery by transcrani...

متن کامل

The Impact of Hemodialysis and Arteriovenous Access Flow on Extracranial Hemodynamic Changes in End-Stage Renal Disease Patients

In this study, we characterized cerebral blood flow changes by assessment of blood flow parameters in neck arteries using carotid duplex ultrasonography and predictive factors for these hemodynamic changes. Hemodynamic variables were measured before and during hemodialysis in 81 patients with an arteriovenous access in their arm. Hemodialysis produced significant lowering in peak systolic veloc...

متن کامل

Comparing the Effect of Simple Filtration Hemodialysis and Ultrafiltration Hemodialysis on Arterial Oxygen Saturation and Blood Pressure in Chronic Dialysis

Background and purpose: Hypoxemia and hypotension are important complications of hemodialysis in patients with chronic renal failure that are linked to several factors, including the type of filters used. The aim of this study was to compare the effect of simple filtration hemodialysis and ultrafiltration hemodialysis on blood pressure and blood arterial oxygen level. Materials and methods: In...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Home hemodialysis international. International Symposium on Home Hemodialysis

دوره 3 1  شماره 

صفحات  -

تاریخ انتشار 1999