Error bounds for EEG and MEG dipole source localization.

نویسندگان

  • J C Mosher
  • M E Spencer
  • R M Leahy
  • P S Lewis
چکیده

General formulas are presented for computing a lower bound on localization and moment error for electroencephalographic (EEG) or magnetoencephalographic (MEG) current source dipole models with arbitrary sensor array geometry. Specific EEG and MEG formulas are presented for multiple dipoles in a head model with 4 spherical shells. Localization error bounds are presented for both EEG and MEG for several different sensor configurations. Graphical error contours are presented for 127 sensors covering the upper hemisphere, for both 37 sensors and 127 sensors covering a smaller region, and for the standard 10-20 EEG sensor arrangement. Both 1- and 2-dipole cases were examined for all possible dipole orientations and locations within a head quadrant. The results show a strong dependence on absolute dipole location and orientation. The results also show that fusion of the EEG and MEG measurements into a combined model reduces the lower bound. A Monte Carlo simulation was performed to check the tightness of the bounds for a selected case. The simple head model, the low power noise and the few strong dipoles were all selected in this study as optimistic conditions to establish possibly fundamental resolution limits for any localization effort. Results, under these favorable assumptions, show comparable resolutions between the EEG and the MEG models, but accuracy for a single dipole, in either case, appears limited to several millimeters for a single time slice. The lower bounds increase markedly with just 2 dipoles. Observations are given to support the need for full spatiotemporal modeling to improve these lower bounds. All of the simulation results presented can easily be scaled to other instances of noise power and dipole intensity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A study of dipole localization accuracy for MEG and EEG using a human skull phantom.

OBJECTIVE To investigate the accuracy of forward and inverse techniques for EEG and MEG dipole localization. DESIGN AND METHODS A human skull phantom was constructed with brain, skull and scalp layers and realistic relative conductivities. Thirty two independent current dipoles were distributed within the 'brain' region and EEG and MEG data collected separately for each dipole. The true dipol...

متن کامل

MEG/EEG hybrid method for source localization of a dipole with radial component

MEG is a useful method to know brain activities, and has a remarkable feature that the source location is estimated with high accuracy. However MEG is insensitive to a radial current dipole, because a radial dipole in a sphere makes no magnetic field outside the sphere and the shape of human head resembles a sphere. To realize more accurate localization, there is a requirement to estimate a rad...

متن کامل

Minimum-norm cortical source estimation in layered head models is robust against skull conductivity error☆☆☆

The conductivity profile of the head has a major effect on EEG signals, but unfortunately the conductivity for the most important compartment, skull, is only poorly known. In dipole modeling studies, errors in modeled skull conductivity have been considered to have a detrimental effect on EEG source estimation. However, as dipole models are very restrictive, those results cannot be generalized ...

متن کامل

Conductivity Estimation with Eeg/meg Brain Source Localization in a Finite Element Head Model

Brain source localization with EEG and MEG modalities provides a useful means of identifying and localizing bioelectric source in the brain. Source localization has been used as an important tool in neuroscience and in clinical applications. Due to modern imaging technology, one can construct a subject specific volume conductor model from a set of MRI or CT images that can improve the accuracy ...

متن کامل

Interpretation of MEG spike source localization in frontal lobe epilepsy with multiple independent spike foci

Magnetic source imaging using a whole-head MEG system provides a more accurate localization of epileptic focus than other routinely used noninvasive methods such as scalp video EEG and magnetic resonance imaging (MRI) [1-3]. However, MEG source localization, as estimated by the single dipole and spherical model, may not fully describe an epileptic region that includes extensive or multiple epil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Electroencephalography and clinical neurophysiology

دوره 86 5  شماره 

صفحات  -

تاریخ انتشار 1993