PURPOSE To evaluate the medium-term outcomes of total hip replacement (THR) using a thin highly cross-linked polyethylene (HXLPE) liner in an Asian population. METHODS Medical records of 20 men and 44 women aged 26 to 80 (mean, 59) years who underwent 80 THRs using a thin HXLPE liner by a single surgeon were reviewed. Indications for THR included dysplasia (n = 26), avascular necrosis (n=26), osteoarthritis (n = 22), rheumatoid arthritis (n = 4), and ankylosing spondylitis (n = 2). The surgical technique, implant used, and rehabilitation protocol were standardised. Radiographs were evaluated for cup migration and peri-implant radiolucency. Femoral head penetration was assessed at day 1 and last follow-up using the Kang modification of the Dorr and Wan method and the PowerPoint method. RESULTS After a mean follow-up of 7.5 (range, 5.0-11.9) years, no patient had undergone acetabular revision. Two hips were revised for the femoral stem. Femoral head penetration did not correlate with sex, age at surgery, hip pathology, acetabular inclination angle, cup size, or liner thickness. The maximum femoral head penetration was 0.09 mm/year, which was below the osteolysis threshold of 0.1 mm/year. The mean ± standard deviation femoral head penetration was 0.29 ± 0.12 mm (or 0.04 ± 0.02 mm/year) by the PowerPoint method and 0.17 ± 0.22 mm (or 0.02 ± 0.03 mm/year) by the Kang modification of the Dorr and Wan method. Femoral head penetration correlated with the number of years of follow-up (p = 0.012). CONCLUSION The use of a thin HXLPE liner in primary THR for patients with small acetabulum achieved good outcomes after a mean of 7.5 years.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contact stress assessment of conventional and highly crosslinked ultra high molecular weight polyethylene acetabular liners with finite element analysis and pressure sensitive film.

Stress magnitude and distribution of both conventional polyethylene versus a crosslinked polyethylene in the liner of a total hip replacement (THR) were examined using finite element analysis and pressure sensitive film. Both types of polyethylene were assessed against head sizes of 22 and 28 mm with 5-mm thick polyethylene liners and head sizes of 28, 38, and 46 mm with 3-mm thick polyethylene...

متن کامل

Total hip replacement in the congenitally dislocated hip using the Paavilainen technique

BACKGROUND AND PURPOSE Total hip replacement (THR) in congenitally dislocated hips (CDHs) according to Paavilainen includes placement of the cup in the original acetabulum and an extended trochanteric osteotomy with distal advancement of the trochanter. There have only been a few reports describing the outcome of this technique. Thus, we report the results of 19 THRs using the Paavilainen techn...

متن کامل

Polyethylene Oxidation in Total Hip Arthroplasty: Evolution and New Advances

Ultra-high molecular weight polyethylene (UHMWPE) remains the gold standard acetabular bearing material for hip arthroplasty. Its successful performance has shown consistent results and survivorship in total hip replacement (THR) above 85% after 15 years, with different patients, surgeons, or designs. As THR results have been challenged by wear, oxidation, and liner fracture, relevant research ...

متن کامل

Reconstruction of the Acetabulum in Developmental Dysplasia of the Hip in Total Hip Replacement

Developmental dysplasia of the hip (DDH) or congenital hip dysplasia (CDH) is the most prevalent developmental childhood hip disorder. It includes a wide spectrum of hip abnormalities ranging from dysplasia to subluxation and complete dislocation of the hip joint. The natural history of neglected DDH in adults is highly variable. The mean age of onset of symptoms is 34.5 years for dysplastic DD...

متن کامل

The rate of wear of second-generation highly crosslinked polyethylene liners five years post-operatively does not increase if large femoral heads are used.

AIMS The increased in vivo resistance to wear of highly crosslinked polyethylene (HXLPE) in total hip arthroplasty (THA) has led to an increased use of larger articulations which have been shown to reduce the incidence of early dislocation. To date, there are few reports of the wear of larger articulations using second generation HXLPE liners. Our prospective cohort study measured the bedding-i...