Intraobserver variation in Doppler ultrasound assessment of pulmonary artery pressure.
نویسندگان
چکیده
Intraobserver variation associated with the non-invasive assessment of pulmonary artery pressure (PAP), using measurement of pulmonary artery Doppler derived systolic time intervals, was investigated. Forty pairs of independent ultrasound examinations of the pulmonary artery were performed by a single observer in 20 preterm infants, median gestation 27 weeks (range 24-31 weeks). Median age at study was 17 days (range 1-47 days). paired measurements of acceleration time (AT), ratio between acceleration time and right ventricular ejection time (AT:RVET), corrected AT, and corrected AT:RVET were compared to assess intraobserver agreement. For the corrected AT:RVET ratio, the mean percentage difference between observations was -0.9% (95% confidence intervals -5.0 to 3.1%). The limits of agreement for the two measurements were -26.3 to 24.5%. The coefficient of repeatability was 25.4%. Variation for other indices was similar. Non-invasive assessment of PAP using Doppler derived systolic time intervals is associated with considerable intraobserver variation.
منابع مشابه
Comparative Assessment of Ultrasound Placental Findings in Small for Gestational Age and Normal-Weight Fetuses
Background Small for gestational age (SGA) refers to newborns whose birth weight is less than the 10th percentile for gestational age. The aim of this study was to provide a comparative assessment of ultrasound placental findings in SGA and normal-weight fetuses in singleton pregnant women. Materials and Methods In...
متن کاملNon-invasive estimation of cardiac wall stress by using tissue doppler-echocardiography ultrasound images: People with coronary artery stenosis
In this study, a method for non-invasive estimation of stress on the heart wall in the diastole phase is presented using ultrasound echocardiography and tissue Doppler imaging. The aim of this study was to evaluate the stress on the heart wall as a pre-diagnosis to identify people with coronary artery stenosis. 29 patients with stenosis of more than 70%, 30 patients with stenosis of 50 to 7...
متن کاملPulmonary Artery Pressure in Patients with Markedly Deviated Septum Candidate for Septorhinoplasty
BACKGROUND The nasal septal deviation (NSD) is one of the major causes of nasal obstruction. This condition increases upper airway resistance. In This study we evaluated the mean pulmonary artery pressure (MPAP) in patients with markedly deviated septum. METHODS Sixty two patients with NSD (Age range: 26-45 years, 34 men and 28 women) were included in the study. Mean pulmonary artery press...
متن کاملPresentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall
Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the substitution of the blood pressure changes in the central arteries such as carotid with the blood pressure changes in the brachial results in error in the blood...
متن کاملRespirophasic carotid artery peak velocity variation as a predictor of fluid responsiveness in mechanically ventilated patients with coronary artery disease.
BACKGROUND We studied respirophasic variation in carotid artery blood flow peak velocity (ΔVpeak-CA) measured by pulsed wave Doppler ultrasound as a predictor of fluid responsiveness in mechanically ventilated patients with coronary artery disease. METHODS Forty patients undergoing elective coronary artery bypass surgery were enrolled. Subjects were classified as responders if stroke volume i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Archives of disease in childhood. Fetal and neonatal edition
دوره 75 1 شماره
صفحات -
تاریخ انتشار 1996